Safety Features; Circuit Breaker; Maintenance Schedule; Reminder Of Use - SDMO HX 5000T Manual De Uso Y Mantenimiento

Ocultar thumbs Ver también para HX 5000T:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29

5. Safety features

5.1. Oil cut-out
If there is no oil in the engine sump or if the oil pressure is low, the oil safety mechanism automatically stops the engine to prevent any
damage.
If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.

5.2. Circuit breaker

The set's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out switches. In the event of an
overload and/or short circuit, the supply of electrical energy may be cut.
If necessary, replace the circuit breakers in the generating set with circuit breakers with identical nominal ratings and specifications.

6. Maintenance schedule

6.1. Reminder of use

The maintenance operations to be carried out are described in the maintenance schedule. The interval for this is supplied as a guide
and for generating sets operating with fuel and oil which conform to the specifications given in this manual.
If the generating set is used under extreme conditions, the interval between the maintenance operations must be shortened.

6.2. Maintenance table

Operations to be
Component
whichever deadline
Engine oil
Air filter
Generating set
Strainer and
Sediment bowl
Spark plug
Spark arrester
Valves *
Fuel tank*
Check (replace if
Fuel line*
* Operation(s) must only be carried out by one of our agents.
The air filter must be cleaned more frequently if the generating set is being used in a dusty environment.
Under occasional heavy use, change the oil at least every year.
carried out at
Each time it is
used
is reached first
Check the level
Change
Check
Clean
Clean
Clean
Check / Clean
Clean
Check/adjust*
Clean*
necessary)
First month or
after the first 20
hours
6 months or
3 months or
Every 100
Every 50 hours
hours
Every 2 years*
12 months or
Every 300
hours
•*
•*

Publicidad

Tabla de contenido
loading

Tabla de contenido