Safety Features; Circuit Breaker; Maintenance Schedule; Reminder Of Use - SDMO Diesel 15000 TE Manual De Utilización Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25

5. Safety features

5.1. Circuit breaker

The set's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out switches. In the event of an
overload and/or short circuit, the supply of electrical energy may be cut.
If necessary, replace the circuit breakers in the generating set with circuit breakers with identical nominal ratings and specifications.
5.2. Oil cut-out
If there is no oil in the engine sump or if the oil pressure is low, the oil safety mechanism automatically stops the engine to prevent any
damage.
If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.

6. Maintenance schedule

6.1. Reminder of use

The maintenance operations to be carried out are described in the maintenance schedule. The interval for this is supplied as a guide
and for generating sets operating with fuel and oil which conform to the specifications given in this manual.
If the generating set is used under extreme conditions, the interval between the maintenance operations must be shortened.

6.2. Maintenance table

Operations to be
carried out when
Component
the 1
Fastenings
Check the level
Engine oil
Oil filter
Fuel filter
Air filter
Starter battery
Generating set
Valves *
Injector*
Cooling system*
* Operation(s) to be entrusted to one of our agents.
In case of use in dusty areas, clean the air filter more frequently.
In case of limited use, drain the oil at least once a year.

7. Maintenance procedures

Before carrying out any maintenance operation:
- switch off the generating set.
- disconnect the cap(s) of the spark plug(s) and disconnect the starter battery (if fitted).
Warning
Only use original parts or equivalent parts: risk of damage to the generating set.
7.1. Checking bolts, nuts and screws
To prevent faults or breakdowns, carefully check all the nuts, bolts and screws on a daily basis.
Inspect the entire generating set before and after each use.
Tighten any loose nuts or bolts.
Danger: The cylinder head bolts must be tightened by a specialist. Refer to the agent for your region.
Each time
st
due date is
it is used
attained
Check
Change
Replace
Replace
Check
Clean
Check
Clean
Check*
Check*
Clean
Every
After:
month
st
1
month
or
or
Every 10
first 50 hours
hours
Every
Every
6 months
or
or
Every 100
Every 250
hours
Every
year
year
or
Every 500
hours
hours
•*
•*
•*

Publicidad

Tabla de contenido
loading

Tabla de contenido