BTL7-S5_ _ (_)-M_ _ _ _-J-DEXC-TA12
Magnetostrictive Linear Position Sensor – Rod Style
8
Technical data
8.1
Accuracy
The specifications are typical values at DC 24 V and room
temperature, with a nominal length of 500 mm in
conjunction with the BTL-P-1013-4R, BTL-P-1013-4S or
BTL-P-1012-4R magnet or with the BTL2-S-6216-8P-Ex,
BTL2-S-5113-4K-Ex, BTL2-S-4414-4Z-Ex or
BTL2-S-4414-4Z01-Ex float.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply. Special versions are indicated by the
suffix -SA on the part label.
Position resolution
Non-linearity at
Nominal length 25...5500 mm
Resolution ≤ 10 µm
Resolution > 10 µm
Nominal length
5501...7620 mm
Hysteresis
Repeat accuracy
Temperature coefficient
1)
Velocity resolution
Min. detectable velocity
Max. detectable velocity
8.2
Ambient conditions
Operating temperature
Storage temperature
Humidity
Rod pressure rating (when
installed in hydraulic cylinders)
Shock rating
Continuous shock
per EN 60068-2-27
2), 3)
Vibration
per EN 60068-2-6
2), 3)
Degree of protection per
IEC 60529
www.balluff.com
1, 2, 5, 10, 20, 40,
50, 100 µm
(additionally 200,
500, 1000 µm with
BTL7-S510...)
≤ ±30 µm
≤ ±2 LSB
±0.02 %
≤ ±7 µm
≤ ±5 µm (typ.
±2.5 µm)
≤ 15 ppm/K
0.1 mm/s
1 mm/s
10 m/s
–40°C...+80°C
–50 °C...+85 °C
< 90%, non-condensing
≤ 600 bar
100 g/6 ms
100 g/2 ms
12 g, 10...2000 Hz
IP68
2), 4)
Ignition protection "d"
Flameproof enclosure
8.3
Supply voltage (external)
Voltage, stabilized
Ripple
Current draw (at 24 V DC)
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength
(GND to housing)
8.4
Output
Configurable bit number
16-32
(only BTL7-S510...)
Coding
Binary or Gray
Characteristic
Rising or falling
SSI data
Position, velocity, absolute
velocity,
differential position, speed
difference (between 2
magnets), error value
SSI clock frequency f
10 kHz...1 MHz
Clk
Behavior at null point
BTL7 standard:
No negative values between
flange and null point
BTL7-S510...:
configurable
Short-circuit protection
Signal lines Data+/–, Clk+/–,
to +36 V or GND
8.5
Communication lines La, Lb
Short-circuit resistance
1) Nominal length = 500 mm, magnet in the middle of the measuring range
2) Individual specifications as per Balluff factory standard
3) Resonant frequencies excluded
4) To maintain the IP68 rating, ensure that the connection at the conduit
opening also meets this standard. Thread sealant should be used on the
conduit opening to ensure protection against moisture ingress. Take
measures to prevent the possibility of internal condensation at the
conduit opening from entering the BTL.
Ensure power is limited to ≤ 5 W!
10...30 V DC
≤ 0.5 V
ss
≤ 120 mA
≤ 500 mA
Up to 36 V
(supply to GND)
Up to 36 V
500 V DC
Signal cable to GND
english
21