DBI SALA 8527910 Instrucciones De Uso Específicas página 5

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
Pwith the setting of the Variable Offset Mast Pin Position (PP) (e.g. Mast Pin Position 4 must use Base Pin Position 4). See
table in Figure 7.
• Level the base by adjusting the screw legs (M) to center the bubble in the level indicator (N). Figure 8
ENVIRONMENTAL HAZARDS: Use of this equipment in areas with environmental hazards may require additional precautions
to reduce the possibility of injury to the user or damage to the equipment. Hazards include, but are not limited to: corrosion,
chemicals, toxic gasses, heat, moving machinery, noise, sharp edges, and electrical hazards. Do not operate during electrical
storms. Contact DBI-SALA if you have questions regarding use of this equipment where environmental hazards exist.
MAINTENANCE: Clean the equipment weekly as required, to thoroughly inspect all welds, labels, pins, fasteners, pulleys,
rollers, brackets and parts. Annually, clean the unit thoroughly, using a damp cloth and a mild soap solution.
INSPECTION:
• Before each installation, inspect each system component in accordance with the individual manufacturer's instructions.
Do not use if visible signs of deterioration or damage are present.
• Before each use, visually inspect per the following steps:
Step 1. Inspect all structural parts for damage: dents, cracked welds, bent or crushed tubes.
Step 2. Inspect all hardware (pins, tri-screws, adjuster screws, nuts, bolts, pulleys, rollers and winch brackets) for
damaged threads, bent, damaged or missing fasteners, or loose fasteners. Check all pulleys and rollers for chips, grooves
and excessive wear. Ensure that all pulleys and rollers turn freely.
Step 3. Inspect all equipment for missing, damaged or otherwise illegible warning stickers. Damaged, missing or otherwise
illegible labels must be replaced before using the hoist.
Step 4. Additional equipment such as winches, self-retracting lifelines (SRLs), work positioning or fall-arrest equipment
being used with your Hoist System must be installed, inspected, maintained and operated according the the manufacturer's
instruction. All installations must be approved to local standards by a qualifi ed person.
Step 5. Do not use the hoist system if inspection reveals an unsafe or defective condition. Repair or replace the sytem
before the next use.
• Weekly: Perform a complete visual inspection of equipment as outlined above. Clean equipment as required to throughly
inspect all welds, labels, pins, fasterners, pulleys, rollers, brackets and parts. Record the inspection date and results in
the inspection and maintenance log in the General Instructions 5902392. If any problems are found do not use. Return to
authorized service center for repair.
• Annually: The Hoist System must be inspected by a competent person at least annually. Record the inspection date and
results in the inspection and maintenance log in the General Instructions 5902392. If any problems are found do not use
until equipment has been repaired by an authorized service center. Do not attempt to modify or repair this unit.
IMPORTANT: Extreme working conditions (harsh environment, prolonged use, etc.) may require increased frequency of
inspections.
PRODUCT LIFE: As long as the Hoist System passes inspection by a competent person,* it may remain in service.
SPECIFICATIONS:
Capacity: One user with a maximum weight of 450 lbs. (205 kg) on line during operation.
Working Load Limit: Minimum 4:1 safety factor
Proof Load Ratings:
• Standard Anchor (C1) Figure 2
Pin Position 1 & 2
Pin Position 3
Pin Position 4
• Optional Anchor (C2) Figure 2
Weight: 100.5 lb. (45.7 kg)
Finish: Fluorescent Green Powdered Coat
Refer to product markings for additional information.
5000 lb. (22.2 kN)
3600 lb. (16 kN)
3000 lb. (13 kN)
5000 lb. (22.2 kN)
5

Publicidad

Tabla de contenido
loading

Tabla de contenido