Sirius SLTC93 Instrucciones Para La Instalación, Uso Y Mantenimiento página 16

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
SL96
Remove the grease filter , as shown in the maintenance section.
Tighten the two screws into the wall bracket (fig. 11A), which are necessary to make the ap-
pliance adhere to the wall; then check that the hood is perfectly flush, otherwise act on the
screws shown in fig. 11B , as follows: tighten the screw if you need to lift the corresponding
side, or unscrew it in case you need to reduce the height.
Carry out the electrical connection by using the appropriate power cord.
Definitively secure the product to the wall by using the screws provided, as shown in fig. 10.
Refit the grease filter: see the maintenance section.
Suctioning mode (top air out-let).
Secure the pipe support bracket (fig. 12) to the wall and/or the ceiling , by using the anchors
and screws provided, in a position corresponding to the centre of the hood.
Connect the motor air out-let flange to the exhaust hole , by using a suitable pipe.
Place the two decorative pipes on the hood exhaust body ; lift the inner pipe as long as it rea-
ches the bracket; then secure it by using the no. 2 self-threaded screws provided .
The suctioning version, with top air out-let, is not available in the SL96 model.
Suctioning mode (rear air out-let).
You will need to rotate the suction motor, as shown in the installation section and in fig. 3 and
4, in order to direct the motor air out-let towards the appliance rear side .
Fit the air out-let grid into place on top of the hood (fig. 13). The use of steel decorative pipes
is not necessary .
In SLTC97 model, it is always necessary to use the steel decorative pipes, even if the rear
air out-let is used.
Filtering mode.
Fit the air out-let grid into place on top of the hood (fig. 13). The use of steel decorative
pipes is not necessary.
In the filtering version, a charcoal filter shall also be used, as shown in the maintenance sec-
tion, according to the model.
In SLTC97 model, it is always necessary to use the steel decorative pipes, even in the
filtering version.
An air deflector is available as an accessory (not for SL96 model ), in order to direct the air
coming out of the motor towards the grids of the steel decorative pipes (fig. 14); the air de-
flector shall be connected to the motor air out-let with a suitable pipe, which is not supplied
with the product.
16

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido