Objetos Para Ajustes De Red - Festo CPX­ FB36 Manual De Instrucciones

Tabla de contenido

Publicidad

C. Objetos de EtherNet/IP del CPX-FB36
C.2

Objetos para ajustes de red

C.2.1 "Device Level Ring Object"
C-8
Clase de objeto: 71
Instancias:
1
Atr.
Acceso
Descripción
N.°
1
Get
Current network topology mode
0: Linear
1: Ring
2
Get
Current status of network
0: Normal
1: Ring Fault
2: Unexpected loop detected
3: Partial network fault
4: Rapid fault / restore cycle
10
Get
Active Supervisor Address
– Supervisor IP address
– Supervisor MAC address
12
Get
Capability Flags
Bit 0:
Bit 1:
Bit 2 ... 4: Reserved. Shall be set
Bit 5:
Bit 6 ... 31: Reserved. Shall be set
Bits 0 and 1 are mutually exclusive
1) è Especificación de EtherNet/IP, capítulo 9-5.4
Tab. C/6: Ajustes de red con objeto Device Level Ring
d
Announce-based
1)
RingNode
Beacon-based
1)
RingNode
to zero
Supervisor Capable
to zero
Festo CPX-FB36-ES es 1611a Español
Tipo
USINT
USINT
STRUCT of
UDINT
ARRAY of
6 USINT
DWORD

Publicidad

Tabla de contenido
loading

Tabla de contenido