Descargar Imprimir esta página

Air For Combustion - EdilKamin SIDE PLUS 50x50 N Manual De Instrucciones

Chimenea de leña

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47

AIR FOR COMBUSTION

AIR FOR COMBUSTION
For the replace to work correctly, it is essential for the com-
For the replace to work correctly, it is essential for the com-
bustion air to be introduced into the combustion chamber by
bustion air to be introduced into the combustion chamber by
means of a pipe which links the external environment to one of
means of a pipe which links the external environment to one of
the air boxes located under the replace (E Fig. 4).
the air boxes located under the replace (E Fig. 4).
To hook up the said piping, a 14 cm connection must be ap-
To hook up the said piping, a 14 cm connection must be ap-
plied to the chosen vent.
plied to the chosen vent.
The inner section of the piping be at least 150 cm
The inner section of the piping be at least 150 cm
whole length.
whole length.
AIR FOR HEATING
AIR FOR HEATING
• •
CIRCULATION
CIRCULATION BY NATURAL CONVECTION
BY NATURAL CONVECTION
The ambient air enters the structure from below the replace
The ambient air enters the structure from below the replace
(G - Fig. 5), is heated, and rises by convection along the cavity
(G - Fig. 5), is heated, and rises by convection along the cavity
at the rear of the combustion chamber, exiting hot from the
at the rear of the combustion chamber, exiting hot from the
vents (D/F - Fig. 5) on the cover of the hood.
vents (D/F - Fig. 5) on the cover of the hood.
• •
CIRCULATION BY FORCED VENTILATION
CIRCULATION BY FORCED VENTILATION
(by a Technician)
(by a Technician)
To connect the forced ventilation, proceed as follows:
To connect the forced ventilation, proceed as follows:
- Connect the two connectors M and F ( g. 6).
- Connect the two connectors M and F ( g. 6).
- Extend the electric wire from the regulator (r - g. 6) to an
- Extend the electric wire from the regulator (r - g. 6) to an
electric socket.
electric socket.
- The wire with the sensor (s - g. 6) must be extended to one
- The wire with the sensor (s - g. 6) must be extended to one
of the hot air exit vents (b - g. 7) normally positioned on the
of the hot air exit vents (b - g. 7) normally positioned on the
mantel.
mantel.
- The sensor must be xed into the hole of the vent.
- The sensor must be xed into the hole of the vent.
check that the sensor wire does not interfere with the sliding
check that the sensor wire does not interfere with the sliding
door.
door.
- Afterwards, insert the plug into the 230 V mains socket.
- Afterwards, insert the plug into the 230 V mains socket.
LEAVE THE NON-DUCTED VENTS FREE
LEAVE THE NON-DUCTED VENTS FREE
N.B.: the skirting of the covering must be removable to
N.B.: the skirting of the covering must be removable to
allow inspection of the fan
allow inspection of the fan
• •
TRANSFORMATION FROM NATURAL CONVEC-
TRANSFORMATION FROM NATURAL CONVEC-
TION CIRCULATION TO FORCED VENTILATION
TION CIRCULATION TO FORCED VENTILATION
CIRCULATION (only by a Technician and with the cove-
CIRCULATION (only by a Technician and with the cove-
rings not tted)
rings not tted)
Proceed as follows:
Proceed as follows:
- Attach the fan to the plate under the replace (Fig. 8) with the
- Attach the fan to the plate under the replace (Fig. 8) with the
screws provided
screws provided
- Continue with the electrical connections as described above
- Continue with the electrical connections as described above
INSTALLATION
along its
along its
2 2
Fig. 4
G
Fig. 5
Fig. 6
Fig. 7
Fig. 8
- 25
-
D
connection
fan
clamp
230 V mains
sensor
sonda
sonda
regulator
regolatore
regolatore
230 V mains
rete 220V
rete 220V
fan
ventilatore
ventilatore
combustion air
E
vent
F
grille
sensor
regulator
vent (b)
bocchetta (b)
bocchetta (b)

Publicidad

loading

Este manual también es adecuado para:

Side plus 50x50 v