TROUBLESHOOTING
The appliance has been tested before being put
into service. The information provided below is in-
tended to assist in the identification and correction
of any anomalies and malfunctions which might oc-
cur during use.
The user can solve some of these problems him-
self, but for others specific technical knowledge or
skill is required, and so they must only be carried
Fault
Smell of gas.
The pilot light does not ignite.
The pilot light goes out.
The pilot light ignites but the
burner remains off.
The flame is yellow.
FAULT
out by qualified staff with recognised experience
acquired in the specific sector of operation.
For all requirements contact the agents or
the headquarters of Angelo Po which can
be found in the contacts section of the web-
site http://www.angelopo.com.
Causes
Occasional leak because flame
has gone out.
The spark ignition devices are not
working.
Air in pipelines due to long period
out of use.
The thermocouple has not
warmed up enough.
Burner dirty, heat exchange pipes
clogged, condensation drips.
- 13 -
Important
Remedies
Turn off the gas supply tap and
ventilate the room.
Check that the ignition devices
are in good working order.
Light by hand with a
naked light.
Information
Contact the after-sales
service.
Make more attempts to light
the flame.
Make more attempts to light
the flame.
Check the condition of the
thermostat and activate any
ignition enabling device.
Information
Contact the after-sales
6
service.
English
IT
GB
DE
FR
ES