Cleaning; Safety Inspection - Siemens SIMOTICS M-1PH818 Serie Instrucciones De Servicio

Ocultar thumbs Ver también para SIMOTICS M-1PH818 Serie:
Tabla de contenido

Publicidad

G3G280-BR04-M7
Motor not turning
Mechanical blockage
Line voltage faulty
Faulty connection
Broken motor winding Replace device
Thermal overload
protector activated
Deficient cooling
Ambient temperature
too high
Item no. 56754-5-9970 · ENU · Change 200100 · Approved 2018-10-04 · Page 11 / 12
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
Switch off, isolate
from supply and
remove mechanical
blockage.
Check line voltage,
restore power supply.
Attention! The error
message resets
automatically.
Device restarts
automatically without
warning.
Isolate from supply,
correct connection;
see connection
diagram.
Allow motor to cool

6.1 Cleaning

off, locate and rectify
cause of error,
release restart lockout
if necessary
Improve cooling. Let
the device cool down.
To reset the error
message, switch off
the line voltage for at
least 25 s and then

6.2 Safety inspection

switch it on again.
Alternatively, reset
the error message by
applying a control
signal of < 0.5 V to
Din1 or by shorting
Din1 to GND.
Reduce the ambient
temperature. Let the
device cool down.
What to check
To reset the error
Contact
message, switch off
protection
the line voltage for at
cover for
least 25 s and then
intactness or
switch it on again.
damage
Alternatively, reset
Device for
the error message by
damage to
applying a control
blades and
signal of < 0.5 V to
housing
Din1 or by shorting
Fastening the
Din1 to GND.
cables
Insulation of
cables for
damage
Tightness of
cable gland
Abnormal
bearing noise
Impermissible point of
operation (e.g. back
pressure too high)
In the event of further malfunctions, contact ebm-papst.
NOTE
Damage to the device during cleaning
Malfunction possible
→ Do not clean the device using a high-pressure cleaner.
→ Do not use acid, alkali or solvent-based cleaning agents.
→ Do not use any pointed or sharp-edged objects for cleaning
NOTE
High-voltage test
The integrated EMC filter has Y capacitors. The tripping current
is exceeded when AC testing voltage is applied.
→ Test the device with DC voltage when you perform the
legally required high-voltage test. The voltage to be used
corresponds to the peak value of the AC voltage required by
the standard.
How to check
How often
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
acoustic
At least every
6 months
Correct the operating
point. Let the device
cool down.
To reset the error
message, switch off
the line voltage for at
least 25 s and then
switch it on again.
Alternatively, reset
the error message by
applying a control
signal of < 0.5 V to
Din1 or by shorting
Din1 to GND.
What action?
Repair or
replacement of
device
Replacement of
device
Fasten
Replace cables
Retighten,
replace if
damaged
Replace device
325