Cable Routing; Factory Settings - Siemens SIMOTICS M-1PH818 Serie Instrucciones De Servicio

Ocultar thumbs Ver también para SIMOTICS M-1PH818 Serie:
Tabla de contenido

Publicidad

K3G280-RR04-H9
Siemens AG PD LD Nbg.

4.3.3 Cable routing

Water must be prevented from reaching the cable gland along the cable.
NOTE
Damage caused by moisture penetration.
Moisture can penetrate into the terminal box if water is
constantly present at the cable glands.
→ To prevent the constant accumulation of water at the cable
glands, the cable should be routed in a U-shaped loop
wherever possible.# If this is not possible, a drip edge can
be produced by fitting a cable tie directly in front of the cable
gland for example.
When routing the cable, make sure that the cable glands are located at
the bottom. The cables must always be routed downward.

4.4 Factory settings

Factory settings made for the device by ebm-papst.
Mode parameter set 1
PWM control
Mode parameter set 2
PWM control
Fan/device address
01
Max. PWM / %
100
Min. PWM / %
10
Save set value to
No
EEPROM
Set value requirement
Analog (linear)
Direction of action
Positive (heating)
parameter set 1
Direction of action
Positive (heating)
parameter set 2
248
Item no. 55769-5-9970 · ENU · Change 94781 · Approved 2017-09-29 · Page 8 / 12
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Simotics m-1ph822 serieSimotics m-1ph828 serie

Tabla de contenido