NEW INSTALLATION
EXAMPLE 1
A
B
A: Air convection outlet. Minimum section 120cm
B: air inlet from room. Minimum section 120cm
For the insert to operate correctly, a minimum side of 20 mm and rear space of 10 mm must be guaranteed; the coatings must be made
of non- ammable material.
IMPORTANT: ALL THE OPENINGS CREATED FOR THE CORRECT AIR CIRCULATION MUST PREVENT THE ENTRY OF
HAZARDOUS PARTS BY USING SPECIFIC GRILLES, BUT STILL GUARANTEEING THE MINIMUM AIR FLOW REQUIRED.
THE PIPE FOR FUMES OUTLET MUST ALWAYS MAINTAIN A MINIMUM DISTANCE OF 50 MM FROM INFLAMMABLE PARTS.
TO SAFEGUARD FROM ANY OVERHEATING, THE INSERT IS SUPPLIED WITH A PROBE THAT ANALYSES THE
TEMPERATURE INSIDE THE STRUCTURE
AND INTERVENES BY REDUCING THE FUNCTIONING POWER.
A
B
.
C: Air convection outlet. Minimum section 240cm
2
D: air inlet from room. Minimum section 240cm
.
2
ENGLISH
EXAMPLE 2
C
D
.
2
.
2
51