Generator o
START
The START phase is in progress
PELLET LOADING
Continuous pellet feeding is in progress during the ignition state
IGNITION
The phase dedicated to ignition is in progress
PREPARATION
The ame stabilisation phase is in progress
WORK
The generator has reached operating capacity and is working on user settings
MODULATION
The generator is working at minimum capacity
FINAL CLEANING
The cleaning cycle is in progress which is required to cool the machine before it is switched o
STAND BY
Generator o but in stand-by to reignite autonomously if required by operating requests
The generator is requested to turn on during the shut-down phase. If activated, the generator will automatically
COOLING STAND BY
turn on again as soon as safety conditions permit it to do so
BLACK OUT
The generator is cooling after a power cut. Once cooling is completed, it will re-start automatically
STAND BY
The auto blow is in progress to keep the burn pot
AUTO BLOW
clean and maximise combustion e ciency
The pellet hopper is empty.
EMPTY HOPPER
Check for the presence of pellets in the hopper.
Contact the after-sales centre.
This indication means that you have 60 seconds to close the hatch/door and the pellet lid.
CLOSE
After 60 seconds have passed, the stove will enter "DEPR ALARM" during the ignition phase while during
HOPPER STOVE
normal operation, the stove will enter "COOLING STAND BY" and then, restart automatically when the conditions
DOOR
are right (clod stove, etc.).
UPDATE
FUMES MOTOR
Fumes motor fault
FAULT
FUMES PROBE
Fumes probe fault
HOT FUMES
High fumes temperature
NO
The pellet hopper is empty
Pellet feed calibration inadequate
IGNITION
NO
IGNITION
No current during the ignition phase
BLACK OUT
The pellet hopper is empty
NO FLAME
No pellet load
The auger motor is not loading the pellets
The door is not closed correctly
DEPR ALARM
The combustion chamber is dirty
The fumes exhaust pipe is blocked/dirty
AUGER CONTROL
Abnormal pellet loading
ALARM

DISPLAYS

ALARMS

EXPLANATION
ENGLISH
REASON
SOLUTION
Contact the after-sales centre
Contact the after-sales centre
Check the pellet ow (see "Pellet load adjustment"). If the problem
is not solve, contact a quali ed technician
Make sure there are pellets in the hopper.
Adjust the pellet ow (see "Pellet load adjustment").
Check the procedures described in the "Ignition" chapter.
Take the stove to o conditions using key 1 and repeat the
procedure described in the "Ignition" chapter.
Make sure there are pellets in the hopper.
Adjust the pellet ow (see "Pellet feed adjustment").
Check hermetic door closure.
Check cleanliness of the fumes pipe and the combustion chamber.
Contact after-sales centre