RADIO CONTROL
CONFIGURATION
RADIO CONTROL CODING PROCEDURE:
1. Disconnect the power supply to the stove.
2. Press the keys
and
3. Using keys
and
OK
4. Power the stove. Con rm the selected unit within 10 seconds (the LED will ash on the radio/emergency card) by pressing the OK key
on the remote control.
5. The LED on the radio/emergency card will remain on for 5 seconds to con rm the new con guration.
6. If the con guration was unsuccessful, the display will read "
OK
THE RADIO CONTROL IS ALREADY CONFIGURED WITH "RADIO ID" 0". IF THERE IS ANOTHER STOVE, TO AVOID
INTERFERENCES, A NEW CONFIGURATION MUST BE PERFORMED, MODIFYING ONE OF THE TWO STOVES.
SOME RADIO FREQUENCY DEVICES E.G. MOBILE PHONES, ETC. MAY CAUSE INTERFERENCE WITH
COMMUNICATION BETWEEN THE RADIO CONTROL AND THE STOVE.
RADIO CONTROL ROOM PROBE
CALIBRATION
This mode allows calibration of the room temperature detected
by the radio control (with ventilation active only). For correct
calibration, it is recommended to position the radio control in a
room with constant temperature and wait for at least two hours.
The procedure for calibration is the following:
Access the menu and reach "TECH MENU".
Set the access key "F4". - "ADJ REMOTE PROBE"
Using the keys
or
calibration.
Save and exit with the key
BATTERY TYPE AND REPLACEMENT
To insert/replace the batteries, su ce it to remove the battery
protection cover at the back of the radio control device ( gure 1).
Insert the batteries in accordance with the symbols imprinted on
the radio control device and on the battery itself.
Three AAA batteries are required for the radio control to
function.
Respect the environment!
Used batteries contain metals that are harmful to the environment, and therefore must be disposed of separately in
special containers.
56
OK
at the same time until the screen to choose RADIO ID appears.
select the new RADIO ID.
adjust the desired ambient
.
OK
OK
". In this case, repeat the procedure.
ENGLISH
( gure 1)