DESCRIPTION OF PARAMETERS
Param.
/1
Room probe calibration (the parameter is expressed in eighths of degree)
/4
Large pin probe calibration (the parameter is expressed in eighths of a degree)
selection third measure input: (0 = evaporator probe, 1 = digital input for micro
/5
port)
/6
configuration digital input (only if /5 = 1, 0 = open contact, 1 = closed contact)
/7
delay time for open door alarm (only if /5 = 1, 0 = excluded)
/C
enabling central probe (0= disabled, 1 = enabled)
/d
Enabling freezing cycle (0= disabled, 1 = enabled)
Pr
lettura sonda camera
Pd
reading evaporator / defrost probe (only if /5 = 0)
Pn
reading large pin probe (only if /C = 1)
r0
adjuster hysteresis (differential)
r1
blast chill chamber setpoint
r2
chamber in positive conservation setpoint
r3
chamber in freezing setpoint
r4
chamber in negative conservation setpoint
r6
product temperature at end of blast chill
r7
product temperature at end of freezing
r9
product setpoint temperature at beginning of time count
rA
enable large pin insertion control (0= disabled, 1 = enabled)
rb
central chamber temperature delta – for first phase large pin insertion control
rc
duration second phase large pin test
rd
chamber temperature threshold for door resistance activation
rE
door resistance hysteresis adjustment
t0
maximum duration at temperature of blast chill cycle
t1
maximum duration at temperature of freezing cycle
C0
compressor activation delay from device start
C2
min. delay between compr. stop and subsequent start
C5
compressor start cycle time in the event of room probe alarm
% of C5 in which the compressor is turned on in case of chamber probe alarm
C6
for positive conservation
% of C5 in which the compressor is turned on in case of chamber probe alarm
C7
for negative conservation
delay time for compressor deactivation from door open (only if /5 =1)
C8
(0 = excluded)
d0
automatic defrost interval in conservation (0 = excluded)
type of automatic defrost in conservation or pre-cycle
d1
(0 = at resistance, 1 = at hot gas, 2 = air)
d2
end-of-defrost temp. (relating to evaporator temper. if /5 = 0)
d3
max. defrost duration (0= defrost never activated)
enable defrost at beginning of blast chill cycle / freezing
d4
(0 = disabled, 1 = enabled)
d5
delay enabling defrost from beginning of conservation (0 = excluded)
compressor delay control at beginning of defrost
d6
(0 = delays ignored, 1 = delays respected)
d7
dripping time
I
N
S
T
A
L
L
A
I
N
S
T
A
L
L
A
I
N
S
T
A
L
L
A
Description
MEASUREMENT INPUTS
ADJUSTMENT SETPOINTS
CYCLE TIMETABLE
COMPRESSOR PROTECTION
T
I
O
N
M
A
T
I
O
N
M
A
T
I
O
N
M
A
SERVICE
PARAMETERS
DEFROST
N
U
A
L
-
N
U
A
L
-
N
U
A
L
-
Default
min
-16°C
-40
0
-40
0
0
1
0
60 sec
0
0
0
0
0
- °C
-
- °C
-
- °C
-
+2°C
1
-5°C
-40
+2°C
-40
-25°C
-40
-22°C
-40
+3°C
-40
-18°C
-40
70°C
0
1
0
7°C
0
56 sec
0
-7°C
-40
2°C
1
90 min
0
240 min
0
0 min
0
2 min
0
10 min
1
50 %
0
70 %
0
30 sec
0
6 ore
0
2
0
+8°C
-40
20 min
0
0
0
240 min
0
1
0
2 min
0
MAX
+99
+99
1
1
255
1
1
-
-
-
15
+40
+40
+40
+40
+40
+40
+99
1
+60
255
+40
10
900
900
5
30
99
100
100
255
24
2
+40
99
1
255
1
30
17