- The filter-regulator-lubricator is equipped with a semiautomatic condensation drain
device. This device operates automatically whenever the compressed air supply to the
machine is cut off. Drain the condensation by hand (button 1, fig. 22) when the level
rises above the mark X fig. 22.
- Check daily that the travel screws of the tool head and each bead breaker unit are
operating correctly. The build-up of dirt in this area may impair operation and cause a
hazard.
- Clean the top plate of the self-centring turntable every week: remove any accumulated
dirt and clean with environment-friendly solvents.
- Monthly checks:
• Clean the arms of the tool head and each bead breaker unit, and the relative travel
screws, and lubricate, using environment-friendly solvents only.
• Check the oil level in the air lubricator (fig. 22) and top up if necessary with SAE 20
non-detergent oil to the level Z marked.
• Clean with a dry cloth. Avoid contact with solvents.
• Check the oil flow-rate through the transparent cap K (correct flow-rate: 1 drop of oil
every 4 bead breaking cycles). Adjust if necessary by turning the adjuster screw Y
(fig. 22).
ATTENTION
Keep the working area clean. Never use compressed air, jets of water or solvent to
remove dirt or residues from the machine. When cleaning, take care to avoid creating
and raising dust as far as possible.
WARNING
If the electricity supply fails with the MOUNT/DEMOUNT tool positioned between the
rim and the tyre, proceed as follows:
- Restart the machine without resetting it.
- Use the bead breakers, operating them up and down, to make enough room for the
MOUNT/DEMOUNT tool to be released from the tyre.
LIST OF DISPLAY SIGNALS
"E1":
X AXIS LIMITATION SIGNAL.
THIS APPEARS WHEN THE CURRENT ABSORPTION BY THE LINEAR AC-
TUATOR REACHES AN EXCESSIVE LEVEL.
This signal disappears by inverting the command.
Contact technical service if necessary.
"E2":
Y AXIS LIMITATION SIGNAL.
THIS APPEARS WHEN THE CURRENT ABSORBED BY THE MOTOR THAT
PERMITS VERTICAL HEAD TRANSLATION REACHES AN EXCESSIVE LE-
VEL.
This signal disappears by inverting the command
"E3":
GENERAL MACHINE UNDER-POWERING SIGNAL.
THIS APPEARS WHEN THE MAINS VOLTAGE IS NOT SUFFICIENT FOR
PROPER MACHINE OPERATION.