minimum personal protective equipment,
available in case of emergency, for imme-
diate assistance to victims of: electric shock,
asphyxiation, burns different, eye burns, etc..
DANGER: ELECTRIC SHOCk CAN BE
FATAL
If person is unconscious and electric shock
is suspected , do not touch the person if he
or she is in contact with welding equipment,
or other live electrical parts. Disconnect
(open) power at wall switch and then use
First Aid. Dry wood, wooden broom or other
insulating material can be used to move ca-
bles, if necessary, away from the person.
3.0 BRIEF INTRODUCTION
Your welder belongs to a range of welding in-
verters for MMA - Manual Metal Arc Welding
that adopts the latest pulse width modulation
(PWM) techology and the insulated gate bi-
polar transistor (IGBT) power module to grant
optimal performances: constant current output
to make welding arc more stable and stepless
current regulation. All inverters are fitted with
automatic protection functions: overvoltage,
overcurrent and overtemperature.
3.1 TECHNICAL DATA
NOTE: here below data may differ from
the data on the technical table on the unit.
Always refer to the technical data table on
the unit.
(1 ph)
KVA
Power 60%
V
Uo
A ±10%
Amp. Min-Max
A
Amp. 60974-1
mm
Ø E
-
Insulation
-
Protec. Degree
(1 ph)
KVA
Power 60%
V
Uo
A ±10%
Amp. Min-Max
A
Amp. 60974-1
mm
Ø E
-
Insulation
-
Protec. Degree
160 Amps
230V 50/60HZ
4
65
15 ÷ 160
40% 160
60% 115
1,6 ÷ 4
H
IP22S
200 Amps
230V 50/60Hz
5
65
15 ÷ 200
35% 200 60% 150
1,6 ÷ 5
H
IP22S
4.0 INSTALLATION OF THE
EQUIPMENT
Proper operation of the generator is ensu-
red by adequate installation. The assem-
bly of the inverter must be done by expert
people, following the instructions and in
full respect of the safety standards.
- Remove the welder from the carton box.
BEFORE ATTEMPTING ANY ELECTRI-
CAL CONNECTION CHECk THE DATA
PLATE AND MAkE SURE THAT THE IN-
PUT VOLTAGE AND THE FREQUENCY
ARE THE SAME OF THE MAINS OUTLET
TO BE USED.
EARTHING
- To protect users the welding machi-
nes must be connected properly to the
earth (ground) system (INTERNATIONAL
SAFETY REGULATIONS).
- It is indispensable to earth (ground)
the machine properly with the yellow-
green conductor of the power supply ca-
ble, in order to avoid discharges due to
accidental contacts with earthed objects.
- The chassis (that is conductive) is
electrically connected to the earth con-
ductor. Failure to earth the equipment
correctly can cause electric shocks dan-
gerous to the users.
- Plug the inverter to the mains.
Do not use the generator with input ca-
bles' extensions longer than 10m and
thinner than 2.5mm². Remember to keep
them layed and not wound or entangled.
Do not use the welder with the side panels
partially or completely removed in order
to avoid accidental contacts with inner
live parts.
- The inverter is now ready for use. Make
sure you are welding in a properly ventilated
area and that the ventilation openings of the
machine are not obstructed (poor air ventila-
tion may reduce the duty cycle of the unit and
cause damages). Now you may choose the
welding process by connecting the accesso-
ries as showed in the following pages.
7