8.2 Unlocking access to programming
1. Scroll through the parameters with the buttons
and
until the display shows P008;
2. Access the parameter by pressing the button
3. The display shows alternately the writing
to indicate that the control board
is waiting for the transmission of the unlocking
code;
4. Within 10 sec. press the CH1 of the "TX Master",
the display shows
to the list of parameters;
5. Access to programming is unlocked.
8.3 Unlocking access to programming and global reset
WARNING! This procedure involves the loss of all stored set-
tings.
The procedure allows the unlocking of the control panel without
having to know its unlocking code.
Following this release, you must program the control panel again
and adjust all operating parameters, in particular, remember to
properly set the configuration of parameters. You will also need to
repeat the measurement of impact forces to ensure the installa-
tion compliance to standards.
1. Scroll through the parameters with the buttons
the display shows P008;
2. Access the parameter by pressing the button
3. The display shows alternately the writing
4. Press the button
, the display shows the flashing writing
;
5. Press the button again and hold for 5 seconds (releasing it be-
fore, the procedure is terminated): The display shows the fixed
writing
followed by
parameters;
6. Access to programming is unlocked.
WARNING At the end of the procedure, the display will be blo-
cked on flashing "
" and motor stroke learning must be
carried out again before any other operation can be carried out.
;
before returning
and
until
;
;
, before returning to the list of
39