5.2 ELECTRICAL CONNECTIONS FOR THE SPACE XL/SPACE XXL MODEL
! Risk of malfunction due to improper installation !
! Risk of personal injury and property damage due to electric shocks !
Execute the wiring following the directions of "Table 2" and diagram (Pag. 33).
WARNING To ensure an appropriate level of electrical safety always keep the 230V power supply cables apart (minimum 4mm in the
open or 1 mm through insulation) from low voltage cables (motors power supply, controls, electric locks, aerial and auxiliary circuits
power supply), and fasten the latter with appropriate clamps near the terminal boards.
WARNING Connect to the power supply 230 V ~± 10% 50 Hz through a multi pole switch or a different device that can ensure multi pole
disconnection from the power supply, with a contact opening of 3 mm.
1-2-3-4
Motor 1 encoder output
5-6
Motor 1 output max 5A
7 (+)
7-8
8 (-)
9 - N.O.
9-13
13 - Com
10 - N.O.
10-13
13 - Com
11 - N.O.
11-13
13 - Com
12 - N.C.
12-13
13 - Com
14 (-)
14-15
15 (+)
20 (-)
20-21
21 (+)
16 (+)
16-17
17 (-)
18
Aerial signal input
19
Ground aerial input
CON 1
Connection of motors metallic parts
25 V ~ transformer power supply input
CON 2
CON 3
Courtesy light output
CON 4
Input for NET-NODE / MEMONET connector
CON 5
Input for NET-EXP connector
Operating mode selection jumper:
J4 (jumper)
(closed) = Normal functioning;
(open) = Programming mode;
32
Table 2 "terminal board connections"
Configurable 24V
output 1 max 5W (see P066 for values that can be selected)
Input 4. Unused
Input 3. Unused
Input 2 START. In case of intervention it provokes: the operator opening or closing. It
may operate as "inversion" mode (P049=0) or "step by step" mode (P049=1).
Input 1 PHOTO 1. When enabled (see parameter P050 in the table), activation of
PHOTO 1 provokes: an inversion of direction (during closing), the arrest of the move-
ment (during opening), prevent the start (gate closed). If unused, short circuit.
Stabilized 24 V
power supply output for tested safety devices
24 V
power supply output for auxiliary devices
Configurable 24V
output 2 max 5W (see P062 for values that can be selected)
(AUX + ST)
=
max 200mA