Cleaning And Maintenance - Stanley D 200/8 Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
If for any reason the 13 amp plug fitted to this product
requires replacement it must be wired in accordance with
G
the following instruction:
B
Do not connect the brown (live) or blue (neutral)
to the earth pin marked 'E'
Connect the Blue wire to the terminal marked Neutral (N).
Connect the Brown wire to the terminal marked Live (L).
Connect the Yellow & Green wire to the terminal marked
Earth (E). Ensure that the outer insulation is gripped by
the cord grip and that the wires are not trapped when
replacing the plug cover. The mains lead on this product is
fitted with a 13 amp (BS1363/A) plug. A 13 amp (BS1362)
fuse must be fitted in the plug.
If in doubt consult a qualified electrician
There are no user serviceable parts inside this product
except those referred to in the manual. Always refer
servicing to qualified service personnel. Never remove
any part of the casing unless qualified to do so; this unit
contains dangerous voltages.
Warning!
For your protection if this product is to be used outdoors it
should not be exposed to rain or used in damp locations. Do
not place the product on damp surfaces, use a workbench
if available. For added protection use a suitable residual
current device (R.C.D.) at the socket outlet.
Note: If the mains cable requires replacing it must be
replaced with an identical one and fitted by a
qualified person.
5.4 I/O switch (On/Off) (ref. 8)
5.4.1 D 200/8/24 - D 200/10/24 (Fig. 2a)
DN 200/10/xx - DN 230/10/xx (Fig. 2c)
D 230/10/xx (Fig. 2d) - D 270/10/xx (Fig. 2e)
DN 200/8/6 (Fig. 2f)
To switch on the equipment set the On/Off switch (ref. 8)
to position I.
Move the On/Off switch (ref. 8) to position O to switch off
the equipment.
FUNCTION
Cleaning of intake filter and/or
substitution of filtering element
Draining tank condensate
5.4.2 D 200/8/6 - D 115/8/6 SIL (Fig. 2b)
To switch on the compressor, pull out the red knob (ref. 8)
to position I.
To switch off the compressor, press the red knob (ref. 8) in
again to position O.
on the 3 pin plug.
5.5 Adjusting the pressure
● You can adjust the pressure on the pressure gauge
● The set pressure can be taken from the quicklock
5.6 Setting the pressure switch
The pressure switch is set at the factory.
5.6.1 D(N) 200/8/xx - D 115/8/6 SIL
5.6.2 D 200/10/xx - DN 200/10/xx - D 230/10/xx

6. CLEANING AND MAINTENANCE

Pull the power plug before doing any cleaning and
maintenance work on the appliance.
Wait until the compressor has completely cooled
down. Risk of burns!
Always depressurize the tank before carrying out
any cleaning and maintenance work.
6.1 Cleaning
● Keep the safety devices free of dirt and dust as far as
● We recommend that you clean the appliance
MAINTENANCE RESUMPTIVE TABLE
AFTER THE FIRST
100 HOURS
Periodically and at the end of work
24
(ref. 6) using the pressure regulator (ref. 7).
coupling (ref. 5).
Switch-on pressure 6 bar
Switch-off pressure 8 bar
- DN 230/10/xx - D 270/10/xx
Switch-on pressure 8 bar
Switch-off pressure 10 bar
Warning!
Warning!
Warning!
possible. Wipe the equipment with a clean cloth or blow
it with compressed air at low pressure.
immediately after you use it.