1. Quick instructions for use of the sauna heater
1.1. Check before taking a sauna bath
1.
The sauna room is suitable for taking a sauna bath.
2.
The door and the window are closed.
3.
The sauna heater is topped with stones that comply with the manufacturer's recommendations, the heating
elements are covered with stones, and the stones are piled sparsely.
NOTE! Ceramic rocks are not allowed.
1.2. Operation of the sauna heater controls
The control panel is installed outside the sauna room.
For more detailed installation guide, refer to the specific control panel operating instructions.
2. Information for users
Persons with reduced physical and mental capacity, sensory handicap, or little experience and knowledge about
how the device is operated (e.g. children), should only operate the device while supervised or according to
instructions given by the persons in charge of their safety.
Make sure that children aren't playing with the sauna heater.
2.1. Sauna room
The walls and ceiling of a sauna room should be thermally well insulated. All surfaces that store heat, such as tiled
and plastered surfaces must be insulated. It is recommended to use wooden panel cladding inside the sauna room.
If there are heat storage elements in the sauna room, such as decorative stone, glass etc., note that these ele-
ments may extend the pre-heating period even though the sauna room is otherwise well insulated (see page 5,
section 3.1 Preparing for sauna heater installation).
2.2. Rekommenderad ventilation i bastun
5
4
6
2
Image. 1 Recommended sauna room ventilation
1. Sauna room
2. Washroom
7. A ventilation valve can be installed here to be kept closed while the sauna is heated and during bathing.
Inlet vent can be positioned in the A zone. Make sure the incoming fresh air will not interfere with (i.e. cool down)
the sauna heater's thermostat near the ceiling.
The B zone serves as the incoming air zone, if the sauna room isn't fitted with forced ventilation. In this case, the
exhaust valve is installed min 1m higher than the inlet valve.
DO NOT ISTALL INLET VALVE WITHIN ZONE C, IF THE SAUNA HEATER'S CONTROL THERMOSTAT IS LO-
CATED IN THE SAME ZONE.
5
7
1
1
4
3. Electric sauna heater
4. Exhaust valve
C
C
C
C
1000 mm
B
B
3
3
5. Exhaust flue or channel
6. Door to the sauna room
A
A
A
min
500 mm
1
3