Electric Heating Toggle; Locating The Connecting Box For The Connection Cable In The Sauna Room - Tylo SK 181 Manual De Usario E Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
Model
SK-181 (1101 -181)
18 (9 + 9)
SK-210 (1101 -210)
21 (9 +
SK-260 (1101 -260)
26 (13+13)
Table 1 Connection cable and fuses

3.4 Electric heating toggle

The electric heating toggle applies to homes with an electric heating system.
The contactor case has a connection (marked 55) for controlling the electric heating toggle.
Connector 55 and the heating elements are simultaneously live (230V). Refer to the contactor case operating ma-
nual for more specific instructions.
A
Image. 2 Location for the connection box

3.5 Locating the connecting box for the connection cable in the sauna room

A = Specified minimum safety clearance, see table 2 side 7.
1. Recommended location for the connecting box
2. Silumin box recommended in this area.
3. This area should be avoided. Always use a silumin box.
In other areas, use a heat-resisting box (T 125 °C) and heat-resisting cables (T 170 °C). The
connection box must be clear of obstacles. When installing the connection box to zones 2 or 3,
refer to the instructions and regulations of the local energy supplier.
Power
Sauna heaters
connection cable
H07RN-F /
60245 IEC 66
2
mm
400 – 415V 3N~
kW
2 – Group effect
2 x (5 x 2,5)
5 x 2,5
12)
5 x 6
2 x (5 x 6)
Fuse
Sauna heaters
connection cable
60245 IEC 66
A
2 – Group effect
2 x (3 x 16)
3 x 16
3 x 20
2 x (3 x 25)
A
3.
1.
2.
Fuse
H07RN-F /
2
mm
230V 3~
A
2 x (4 x 6)
2 x (3 x 25)
4 x 6
3 x 25
4 x 10
3 x 35
------
------
6

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sk 210Sk 260

Tabla de contenido