Introduction
Technical Data
Advice for your
safety
Measured sound
value
Measured
vibration value
Use
Mains
connection
ENGLISH
You have high standards and expect to purchase quality goods – quality offered by
Atlas Copco.
We have built a durable and reliable electric power tool for you.
Please read the instructions for use before first operation so you can handle your
power tool effectively and safely.
We are sure that buying an AEG Electric Power Tool from Atlas Copco was the right
choice!
Nominal power
. . . . . . . . . . . . . . . . . . . .
No-load speed
. . . . . . . . . . . . . . . . . . .
Speed under load max.
Percussion rate
Drilling capacity in
Concrete max.
concrete with core drill max.
Weight
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
J
Please pay attention to the safety instructions in the attached leaflet!
J
Dust that arises when working on material containing asbestos or stonework
containing crystalline silicic acid is harmful to the health. Please follow accident
prevention regulations.
J
Appliances used at many different locations including open air must be connected
via a current surge preventing switch.
J
Always wear goggles when using the machine. It is recommended to wear gloves,
sturdy non slipping shoes and apron.
J
Sawdust and splinters must not be removed while the machine is running.
J
Do not pierce the motor housing as this could damage the double insulation (use
adhesives).
J
Always disconnect the plug from the socket before carrying out any work on the
machine.
Only plug-in when machine is switched off.
J
Keep mains lead clear from working range of the machine. Always lead the cable
away behind you.
J
Always use the auxiliary handle, even if the machine has a safety clutch since this
safety clutch only engages when the machine blocks with a jerk.
J
When drilling in walls ceiling, or floor, take care to avoid electric cables and gas or
waterpipes.
Typically the A-weighted noise levels of the tool are:
Sound pressure level = 93 dB (A).
Sound power level = 106 dB (A).
Wear ear protectors!
Measured values determined according to EN 50 144.
Typically the weighted acceleration is : 5,0 m/s
Measured values determined according to EN 50 144.
The pneumatic hammer can be universally used for hammer drilling and chiselling.
Do not use this product in another way as stated for normal use.
Connect only to a single-phase AC current supply and only to the mains voltage
specified on the rating plate. Connection to sockets without earth protection is
possible as the appliance features protective insulation to DIN 57 740/ VDE 0740
and CEE 20. Radio suppression complies with the European standard EN 55014.
When fitting the plug, make sure that the brown (live) wire of this appliance is
connected to the plug terminal marked L or coloured red, and the blue (neutral) wire
of this appliance is connected to the plug terminal marked N or coloured black.
Under no circumstances must the wires of this appliance be connected to the earth
terminal of the plug marked either E, with the earth symbol or coloured green or
green/yellow.
1
0–300 min
. . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . .
1050 W
-1
-1
250 min
-1
3200 min
50 mm
150 mm
8,9 kg
2
.
PNEUMATIC 5000 E