Gasoline:
*
Check the fuel level. Fill to recommended level if low.
*
*
*
Hydraulic oil:
*
Check the hydraulic oil level through the level indicator on the front cover
*
Fill to recommended level, shown on indicator decal, if low.
*
*
*
9.2.2 Starting:
First complete the checklist in section 9.2.1.
*
Turn the fuel cap vent lever to the ON position.
*
Switch the choke lever to its CHOKE position.
*
Turn engine switch to the ON or "1"position.
*
Pull the cord until resistance is felt, let the cord be retracted and then pull fast. Repeat
this if the engine does not start the first time.
*
Switch the choke lever to RUN when the engine has warmed up after approx. 20 - 30 seconds, or
when the engine begins to run irregularly.
NOTE: Start in the RUN position if the engine is still warm. Start in the CHOKE position if the
engine is cold or runs out of gasoline during operation.
NOTE: During equipment testing operations, run the engine for at least 20 minutes or until the
engine reaches operating temperature. (Depending on ambient temperature. Run the
engine longer in colder weather)
12
Use only un-leaded gasoline.
Do not overfill the tank.
Immediately remove any gasoline that spills.
Use only Holmatro recommended hydraulic oil.
Do not overfill the tank.
Immediately remove any hydraulic oil that spills.
Guide the starting cord back after starting.
Gasoline is highly flammable and explosive.
You can be burned or seriously injured when
handling fuel.
Use only Holmatro recommended hydraulic
fluid. Use of hydraulic fluid other than that
recommended may cause damage to the pump.