Any damage arising by not following these warnings are
not covered by the guarantee.
I
PREPARING FOR USE
CAUTION
The preliminary checks and any system adjust-
ments must be performed by qualified autho-
rised personnel, under their own responsibility.
Instructions are provided in the second part of
this manual.
The user must appoint a qualified person able to manage and
run the system, in particular as regards the following operations:
Filling the MaxiJacuzzi
The optimum level is obtained when the water reaches the
level mark on the skimmer (
Verification of water quality, chemical control of pH
and water sanitation.
These checks must be performed frequently to guarantee long-
term water quality, especially if the MaxiJacuzzi
eral persons.
Make sure that ALL the operations described in the
section "Operating instructions for the system user General
Warnings Initial Start- up" have been carried out.
Turn on
the
system's main switch.
WARNING
Do not power the system if the MaxiJacuzzi
not filled with water up to the normal filling lev-
el, as this may damage the pumps. Failure to ob-
serve this warning will immediately invalidate
the warranty.
I
LIMITATION OF ELECTRICAL CONSUMPTION
If there is not enough electrical energy and you decide to ac-
tivate the consumption limiter, the system software must be
configured for proper operation of the spa:
Press and hold the "Light"
til the message"cFn" appears.
If necessary, use the "Up"
scroll the menu until you see "cFn". Press the "Light"
gain to confirm the option.
Now insert the password 123 as follows:
- use the "Up"
and/or "Down"
- confirm the selection by pressing the "Light"
Perform the same steps to insert the other two numbers.
®
with water.
i
2, part B).
is used by sev-
®
key for about 12 seconds, un-
and/or "Down"
keys to insert the first number.
key.
Once you have inserted the password, the display will show
the message I1x (parameter for temperature unit of measure.
Press the "Light"
"x" may be 1 or 0; the default is 1).
Use the "Up"
from 1 to 0 and then confirm the selection with the "Light" * key.
The display will show the message I3 0. Press the "Light"
key again to exit the procedure and memorize the new values.
Make sure you do not modify parameter I3 0. The display will
go off for a moment, and then it will come on again.
- If no key is pressed for 20 seconds, you will exit the proce-
dure and any changes made will not be saved.
NOTES
- When I2 is 0, electrical consumption of the spa is limited to
16A. Under this condition you can simultaneously turn on a
hydromassage pump and the blower. When you turn on the
other pump, the one in operation is shut off but the blower s-
tays on.
If the heater is on, turning on any load (pumps and/or
blower) will disable the heater.
- When parameter I2 is 1, maximum electrical consumption is
selected. Under this condition, it is possible to turn on both
the hydromassage pumps and the blower.
If the heater is turned on, turning on the two hydromassage
pumps (when available) and the blower may cause the heater to
be disabled. In any case, it is enabled 5 minutes after power con-
sumption has reduced sufficiently to permit its use.
- It is not advisable to activate the consumption limiter if the s-
pa is installed where temperatures often drop below 0 °C because
®
is
this limits the anti-freeze protection (see related chapter).
I
CONTROL PANEL AND FUNCTIONS
Follow the instructions provided below to get familiar with us-
ing the control panels. These include the main one (
near the skimmer, and the secondary one (
site side. The secondary one only lets you start the pumps for
the hydromassage, activate the air jets (blowers) and/or turn on
the spotlight.
Note: some models do not have the secondary com-
mand/control panel, only the main one.
When the system is powered on, the display shows the time
alternating with the temperature in the tub.
keys to
If the electric heater is operating, the corresponding symbol al-
key a-
so appears:
31
key again to go to parameter I2x (where
and/or "Down"
.
keys to change "x"
i
6) located
i
7), on the oppo-