Beninca BRAINY Manual De Instrucciones página 17

Ocultar thumbs Ver también para BRAINY:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
Select the 1/2 motors operating mode:
On: only one motor (motor 1) active. Function to be used in the following cases:
- for single motor, to connect M1:4-5-6.
1mot
- for two syncronized motors (for instance overhead door), to connect M1:4-5-6 and M2:7-
8-9. You need to regulate the parameters related to the motor 1, the limit switch entries
M2 are disarmed (not activate).
Off: Both motors operating.
The calculation of residual operating time is activated or deactivated in the event of partial
operations:
On: Calculation of deactivated time. In case of partial operations, the operating time is
not
reset. The following operation restarts for the entire time preset by parameter TM1/TM2.
Off: Calculation of activated time. In case of partial operations, the operating time is sto-
red in memory and then subtracted from the TM1/TM2 parameter value in the following
operation.
The Encoder is enabled or disabled. See section " TYPES OF INSTALLATIONS"
ENC
On: Encoder enabled – The anti-crash sensor is activated.
Off: Encoder disabled – The anti-crash sensor is deactivated.
Enables or disables the programmable code transmitters.
IMPORTANT: The transmitters with programmable code can only be used in conjunction
with the Rolling Code HCS transmitters.
Cvar
On: Radio receiver enabled only for transmitters Rolling Code (ARC or HCS, the first
transmitter sets the operating mode).
Off: Receiver enabled for transmitters Rolling Code HCS and programmable (self-learning
and dip/switch).
Selects the type of electric lock used.
On: Magnetic electric lock, normally fed at 12Vdc.
Before each opening manoeuvre the power supply is interrupted for the time set by the
mloc
parameter TLOC.
Off: Electric lock with latch, normally not fed.
Before each opening manoeuvre power is fed at 12Vdc for the time set by the parameter
TLOC.
The check for integrity of TRIAC is enabled or disabled.
TRK
On: Activated check: if TRAC is faulty, the motor does not start.
Off: the TRIAC is not checked.
The test of photocells to PHOT O input is enabled or disabled.
On: Test is enabled. If the test is negative, no operation is performed. See Fig.1 "PHOTO
TST1
TEST".
Off: Test is disabled.
The test of photocells to PHOT C input is enabled or disabled.
On: Test is enabled. If the test is negative, no operation is performed. See Fig.1 "PHOTO
TST2
TEST".
Off: Test is disabled.
Configuration, AUX2 output.
On: AUX2 Output, preset as open gate light. See "SCA" figure.
2CH
Light switched on with open gate, fast flashing during closure, slow flashing during open-
ing, light off with closed gate.
Off: AUX2 output, preset as second radio channel of the built-in receiver.
The thrust function in the closing phase is activated or deactivated by this logic.
On: the operation in the closing phase is carried out at normal speed during the last se-
BB
cond (braking is disabled). In this way, a better hooking of the electric lock is performed.
Off: disabled function.
The automatic switching is activated/deactivated in Service Man mode.
On: If the sensitive edge remains activated for at least 10 seconds with open or closed
Horm
gate, the control unit automatically switches to Service man mode.
Off: Disabled function.
The remote storage of the radio transmitter codes is enabled or disabled (see par. REMO-
TE LEARNING).
REM
On: Enabled remote storage
Off: Disabled remote storage.
(OFF)
EN
(ON)
(OFF)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
17

Publicidad

Tabla de contenido
loading

Tabla de contenido