DITEC E1 Manual De Instalación página 15

Tablero electrico para automacion a un motor con radio incorporado
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
6.
EXAMPLE APPLICATIONS FOR SLIDING GATES AND SLIDING DOORS
When control panel is used for sliding automations operations:
-
set JR6=OFF;
-
set TM=MAX;
-
(Fig. 6.1) connect opening and closing limit switches N.C.
contacts to plug 12-0-11;
With the above connections, when limit switches operate the
wing stops.
In the event of obstacle detection, the wing stops and releases
during opening operation and reopens during closing opera-
tion.
(Fig. 6.2) Select the proper opening direction by means of
DIP2.
7.
EXAMPLE OF PARALLEL AUTOMATIONS
B
A
It is possible to command two automations [A] and [B] side by
side, making the connections indicated in fig. 7.1.
Commands 1-5 and the remote control (with DIP1=ON) are
equivalent to a total opening command.
To manage both automations with a single remote control, do
not use the radio receivers on the control panels, but insert a
BIXLR22 receiver.
The automatic closing is obtained by regulating the TC trimmer
not at the maximum, and in the same position in both control
panels.
Note: the opening and closing movements are not synchronised.
12 0 11
JR6=OFF
12 11 0 1 5 6 8 9
DIP2=OFF
JR1=NO
JR2=CH1
JR1 JR2
JR3
ON
1 2 3 4
DIP1=ON
DIP2=ON
A
TC<MAX
15
TM=MAX
R1<MAX
Fig. 6.1
DIP2=ON
Fig. 6.2
NO RADIO
ON
1 2 3 4
DIP1=ON
DIP2=OFF
B
TC<MAX
Fig. 7.1
E1 - IP1853
GB

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

E1j

Tabla de contenido