1.

ELECTRICAL CONNECTIONS

1.1 Commands
Command
1
5
N.O.
STEP-BY-STEP WITH
AUTOMATIC CLOSING
STEP-BY-STEP WITHOUT
AUTOMATIC CLOSING
OPENING WITH
AUTOMATIC CLOSING
OPENING WITHOUT
AUTOMATIC CLOSING
1
6
N.O.
CLOSING
1
6
N.C.
SAFETY STOP
1
8
N.C.
REVERSAL SAFETY
DEVICE
1
9
N.C.
STOP
EMERGENCY STOP
1
9
N.O.
HOLD-TO-RUN
FUNCTION
0
11
N.C.
CLOSING
LIMIT SWITCH
TM=MAX
0
11 N.O.
CLOSING
PROXIMITY SWITCH
0
12
N.C.
OPENING
LIMIT SWITCH
TM=MAX
0
12 N.O.
OPENING
PROXIMITY SWITCH
AUX
WARNING: Make a jumper on all NC contacts if not in use. The terminals with the same number are equal. The given operating
and performance features can only be guaranteed with the use of DITEC accessories and safety devices.
Function
With DIP1=OFF and TC<MAX, the closure of the contact activates an
opening or closing operation in the following sequence: open-stop-close-
open.
Note: the stop is not permanent, but has the duration set by TC.
With DIP1=OFF and TC=MAX, the closure of the contact activates an
opening or closing operation in the following sequence: open-stop-close-
open.
With DIP1=ON and TC<MAX, the closure of the contact activates an ope-
ning operation.
With DIP1=ON and TC=MAX, the closure of the contact activates an ope-
ning operation.
With the automation blocked, the closure of the contact activates the opposite
operation compared with that activated before the stop.
With 6→4=OFF, the closure of the contact activates a closing operation.
The opening of the safety contact stops and prevents any movement.
Opening the safety contact triggers a reversal of the movement (reope-
ning) during a closing operation.
Opening the safety contact stops the current operation.
To enable the emergency stop function (e.g. with a specific red button),
connect the opening and closing controls to terminal 9 instead of 1 (9-5,
9-6).
Permanently opening the safety contact enables the operator presence
dependent function.
In this state, the opening (1-5) and closing (1-6) controls function only if
held in the pressed position, and the automation stops when the controls
are released.
Any safety devices, plus the automatic closing, are disactivated.
With DIP2=OFF, the opening of the contact blocks the movement of the
automation during the closing phase.
With DIP2=ON, the opening of the contact blocks the movement of the
automation during the opening phase.
Alternatively, you can connect the limit switch to the fastons 0-11 (in this
case, the terminals 0-11 must not be jumped).
In the event of obstacle detection during closing and before the activation
of the proximity limit switch, the door wing reopens; after the activation
of the proximity limit switch, the door wing blocks against the mechanical
closing stop.
With DIP2=OFF, the opening of the contact blocks the movement of the
automation during the opening phase.
With DIP2=ON, the opening of the contact blocks the movement of the
automation during the closing phase.
Alternatively, you can connect the limit switch to the fastons 0-12 (in this
case, the terminals 0-12 must not be jumped).
In the event of obstacle detection before the activation of the proximity limit
switch while opening, the door wing stops, performing a disengagement
operation; after the activation of the proximity limit switch, the door wing
blocks against the mechanical opening stop.
The control panel has one space for coupling board, type radio receivers,
magnetic loops etc.
The coupling board working mode is selected by DIP1.
Warning: the plug-in cards must be inserted and removed with the power
supply disconnected.
Description
11
GB
E1 - IP1853