• Insert the Razor
dose trimming tool into the filter
™
basket until the shoulders of the tool rest on the
rim of the basket.
• Rotate the Razor
™
forth while holding the portafilter on an angle over
a knock box to trim off excess coffee grinds.
Purging the Group Head
Before placing the portafilter into the group head,
run a short flow of water through the group head
by pressing the 1 CUP button.
Inserting the Portafilter
Insert the portafilter into the group head and
rotate the handle towards the centre until
resistance is felt.
Preset Shot Volume – 1 CUP button
Press the 1 CUP button once to extract
a single shot of espresso at the preset volume
(approx. 30ml).
NOTE
Pressing the 1 CUP or 2 CUP button during
a preset shot volume will immediately stop
the extraction.
10
dose trimming tool back and
Preset Shot Volume – 2 CUP button
Press the 2 CUP button once to extract
a double shot of espresso at the preset volume
(approx. 60ml).
Re-Programming
Shot Volume – 1 CUP or 2 Cup
1. To begin programming, press the Programme
button once.
2. Press 1 CUP or 2 CUP button to start espresso
extraction. Press 1 CUP or 2 CUP button again
once desired volume of espresso has been
extracted. The machine will beep twice to indicate
the new 1 CUP or 2 CUP volume has been set.
Resetting Default Volumes
To reset the machine to the default 1 CUP
and 2 CUP shot volumes, press and hold the
PROGRAMME button until the machine beeps
three times. Release the PROGRAMME button.
NOTE
Default settings: 1 CUP shot volume is approx.
30ml. 2 CUP shot volume is approx. 60ml.
Manual Shot Volume
Press and hold the 1 CUP or 2 CUP button.
The extraction will enter low pressure pre-infusion
until the button is released. When the 1 CUP
or 2 CUP button is released, extraction will
continue at full pressure. Press the 1 CUP
or 2 CUP button again once the desired volume
of espresso has been extracted.