Victron energy BlueSolar MPPT 150/45-Tr Manual página 11

Ocultar thumbs Ver también para BlueSolar MPPT 150/45-Tr:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3.5 Configuration of the controller
Fully programmable charge algorithm (see the software page on
our website) and eight preprogrammed charge algorithms,
selectable with a rotary switch:
Pos
Suggested battery type
Gel Victron long life (OPzV)
0
Gel exide A600 (OPzV)
Gel MK
Gel Victron deep discharge
Gel Exide A200
1
AGM Victron deep discharge
Stationary tubular plate
(OPzS)
Default setting
Gel Victron deep discharge
2
Gel Exide A200
AGM Victron deep discharge
Stationary tubular plate
(OPzS)
AGM spiral cell
3
Stationary tubular plate
(OPzS)
Rolls AGM
PzS tubular plate traction
4
batteries or
OPzS batteries
PzS tubular plate traction
5
batteries or
OPzS batteries
PzS tubular plate traction
6
batteries or
OPzS batteries
Lithium Iron Phosphate
7
(LiFePo
) batteries
4
Note 1: divide all values by two in case of a 12V system and multiply by two
in case of a 48V system.
Note 2: equalize normally off, see sect. 3.8 to activate.
(do not equalize VRLA Gel and AGM batteries)
Note 3: any setting change performed with Bluetooth or via VE.Direct will
override the rotary switch setting. Turning the rotary switch will override prior
settings made with Bluetooth or VE.Direct
Absorption
V
28,2
28,6
28,8
29,4
29,8
30,2
30,6
28,4
9
Equalize
Float
V
V
@%I
nom
31,8
27,6
@8%
32,2
27,6
@8%
32,4
27,6
@8%
33,0
27,6
@8%
33,4
27,6
@25%
33,8
27,6
@25%
34,2
27,6
@25%
27,0
n.a.
dV/dT
mV/°C
-32
-32
-32
-32
-32
-32
-32
0

Publicidad

Tabla de contenido
loading

Tabla de contenido