Storing Operation Settings; Storing Pulse-Tronic Charge; Storing Supply/Diagnostic Mode - Telwin DOCTOR CHARGE 50 Manual De Instrucciones

Ocultar thumbs Ver también para DOCTOR CHARGE 50:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 70
c) CUSTOMISED PULSE-TRONIC
It is possible to select:
- the battery construction technology (fig. A.11)
choosing between:
"WET, GEL, AGM, PbCa"
- the charge current (fig.A.6) choosing between:
"AUTO" - automatic setting according to battery
conditions;
"BOOST" - rapid charge;
- the Ah - customised setting of the battery Ah (fig.
A.2) using 6 predefined values selected using
the "MODE" button (fig. A.23), adjustable at 5 Ah
intervals using the "VOLT" button (fig. A.21), and
"FUNCTION" (fig. A.22).
Ah SETTING - EXAMPLE
15Ah
100Ah
DISPLAY
Note. The final charge voltage depends on the
technology of construction of the battery; to avoid
damaging the battery, pay special attention to the
technical specifications given by the manufacturer.
Construction
Technology
WET
GEL
AGM
PbCa
AUTO
AUTO
The PULSE TRONIC charge process (fig. A.17)
starts when the display stops flashing, each
individual phase is identified on the display (fig.
A.14) and terminates with the message (fig. A.2)
"OK". The battery charge status is displayed
graphically in (fig. A.5). If the charge process is
not successful, an alarm message appears on
the display (fig. A.2) (see alarms list). When the
battery is charged, the battery charger switches
automatically to maintenance mode.
300Ah
15Ah
100Ah
80Ah
75Ah
70Ah
. . . . .
Final charge voltage
6V
12V
7.7V
15.4V
30.8V
7.2V
14.4V
28.8V
7.35V
14.7V
29.4V
8V
16V
7.2V
14.4V
28.8V
7.7V
15.4V
30.8V
END OF CHARGE - EXAMPLE
CHARGE COMBINATION CHART
BATTERY TYPE
AUTO
AUTO
WET
300Ah
AGM
. . . . .
PbCa
100Ah
95Ah
90Ah

3.3.2 STORING OPERATION SETTINGS

It is possible to store the last function modes, so
they are immediately available after any switching
ON/OFF.

3.3.2.1 STORING PULSE-TRONIC CHARGE

Storage of voltage and type of battery, charge
mode.
Procedure:
24V
- Check that the charge clamps are not connected
to a battery;
- Connect the power cable to the mains socket;
- Set the desired charge mode;
32V
- Disconnect the power cable from the mains
socket.
3.3.2.2 STORING SUPPLY/DIAGNOSTIC
MODE
Storage of delivered voltage and current.
Procedure:
- Set the chosen mode and adjust the voltage/
current values as required;
- Turn on the lock settings by pressing, at the same
time, both keys "VOLT" (fig.A.21) and "MODE"
(fig.A.23) for 3 seconds, on the display (fig.A.2)
(fig.A. 4) will appear "LOK on."
- 22 -
BATTERY CURRENT
(T)
AUTO BOOST
AUTO BOOST
GEL
AUTO BOOST
(C)
AUTO
MANUAL "Ah"
AUTO
MANUAL "Ah"
AUTO
MANUAL "Ah"

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pulse 30

Tabla de contenido