Electrical Connections - Hoshizaki IM-240DNE-HC Manual De Instalación

Ocultar thumbs Ver también para IM-240DNE-HC:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
ENGLISH
3) Attach the lower unit (X-type) on the top of the storage bin.
4) Secure the lower unit (X-type) to the storage bin at the rear, by using the
mounting brackets and bolts provided.
5) Remove the shipping tape holding the bin control switch on the drain pan.
Attach the bin control switch to the frame located at the left bottom of the
condensing unit, and secure it using the two screws and the two washers
provided.
6) Before stacking, disconnect the bin control switch leads (with three-way plug)
from the upper or middle unit. Remove the screws and the bin control switch.
When stacking two or three icemakers, the switch for the upper unit will not be
required. Keep it after removal.
7) Attach the upper or middle unit on the lower unit.
8) Secure the two units with the two bolts and the two nuts provided.
9) Place the ice chute (lower or middle unit accessory) and secure it to the
bracket with the two screws.
10) Connect the leads (with three-way plug) located in the lower unit wiring
channel to the upper unit receptacle, unplugged in the above step 6). Secure
the leads using the plastic clamp provided.
Upper Unit
Lower Unit
11) Replace the icemaker panels in their correct position.
Note: If stacking three icemakers, repeat the instructions 6) - 11) for the upper unit. Remember, only ONE bin control is needed
regardless of configuration. The bin control extension leads are pre-wired with the plug and will be found coiled in the
X-type wiring channel.

7. ELECTRICAL CONNECTIONS

This icemaker requires an earth that meets the national and local electrical code requirements.
To prevent possible severe electrical shock to individuals or extensive damage to the unit, install a proper earth wire to the icemaker.
Disconnect the main power supply before any maintenance, repairs or cleaning is undertaken.
* This appliance requires a separate 220 - 240VAC, 13A supply. The electrical supply must be protected by a suitable circuit
breaker.
* Stacked icemakers should each have a separate receptacle, but they must all be connected in parallel to the same single
phase supply or circuit with sufficient ampacity. In addition and to avoid nuisance tripping, individual circuit breakers for each
machine should not be used.
* The main control box fuse is rated at 5A and should only be replaced by a qualified service engineer.
Screw
Nut
Ice Chute
Bolt
Ice Chute
Bracket
WARNING
THIS APPLIANCE MUST BE EARTHED
Drain Pan
Upper Unit
Remove Bin
Control Switch
Receptacle
Plug
Upper Unit
Lower Unit
6
Bin Control Switch
Handle with care
Screw
Frame
Washer
Bin Control Switch
Screw
Disconnect leads
Wiring Channel
Plastic Clamp