Maintenance
General manikin cleaning. Routine disinfection of the entire manikin is not required, but periodic cleaning
of the head, torso, chest skin, and training mat is recommended.These should be washed with a luke
warm soapy solution, and then rinsed with a clean damp cloth. Proper care will maintain the appearance
and general condition of your Little Anne.
To change clicker
Fig. 5
To remove - Fig. 5
Open the chest cover.
Remove the rib plate.
Set the clicker in the "off "
position (outer position).
To change clicker activator - Fig. 7
The clicker activator is located underneath the
rib plate. It is fastened by snapping it in place
over the edge and into the two holes of the rib
plate as illustrated.
To change chest skin - Fig. 8
Unhook the chest skin from its retainers.
Note: For the AED Little Anne model be aware of
wires connecting the chest skin to the battery box
under the rib plate. Disconnect the two wires from
the battery box (when connecting the new chest
skin wires to the battery box it does not matter
which wire goes to which socket).
Press together the sides of the
clicker and lift it up. Push it out
through the opening in the
torso.
Fig. 7
Fig. 8
5
Fig. 6
To install - Fig. 6
Insert the clicker from outside
(with the pad facing upward).
Press the clicker down until it
snaps into place.