11. MAINTENANCE

All maintenance that requires the pump to
be dismantled and reassembled should be
conducted by a specialised technician.
All maintenance should be conducted with the
pump disconnected from the power mains.
EN
Under normal operating conditions, the pump should be
serviced every 12 months (approximately every 2500 hours
of operation). If operating conditions are more severe, reduce
this interval to 6/8 months (approx. 2000 hours). To keep
pump performance unaltered over time, restore correct
impeller distancing plate (see para. 11.2) at each service.
Submit the pump for regular servicing according to the
table below.
Part
Lubricant oil
Mechanical seal
O-rings, seals
Bearings
11.1. Top-up/change of lubricant
Top-up or replace the lubricant using the hole on the plate,
placing the pump upside down (see Fig. 15.3.1). Ensure
that there is the quantity of lubricant stated in the table
15.3.2 in the oil chamber.
Use a non-foaming, non-detergent white mineral oil (CAS
8042475), suitable for coming into contact with food, such
as: VABRIOL ATOXOIL FU 15.
11.2. Adjustment of the distancing plate
(figs. from 15.1.1 to 15.1.2)
Adjust to the minimum possible:
-
the distance between the impeller (1) and the diffuser
(2), by appropriately choosing the washer thickness
(3).
10
Period/Event
Check condition and
level every 6 months.
If there are traces of
water, replace (at each
intervention, replace the
sealing washer).
Check condition in the
event that traces of water
should be seen in the oil.
Replace each time they
are dismantled.
Replace every 3000 hours.

12. NAME PLATE

1
Model
2
Item n°
3
Minimum and maximum flow in l/min
4
Prevalence at minimum and maximum flow in m
5
Maximum prevalence m
6
Motor type (single or three-phase)
7
Power in kW
8
Rated voltage in V
9
Rated current in A
10 Rated frequency in Hz
11 Minimum prevalence in m
12 Number of revolutions per min.
13 Capacitor capacity (single phase only)
14 Capacitor voltage (single phase only)
15 Maximum liquid temperature
16 Pump protection class
17 Insulation class and type of service
18 Weight in kg
19 Serial number
20 Maximum operating depth