Buhler P1.3 Guía Rápida página 14

Bombas de gases de muestreo
Ocultar thumbs Ver también para P1.3:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
P1.3
Sample gas pumps of type P1.3 (12 V DC/24 V DC) and P1.3E (all
voltages) are delivered as standard with a 3 m connecting
cable.
It is essential to connect the protective earth conductor to
the marked protection earth terminal. At model P1.3E
(115 V/230 V) the protective earth has to be connected to the
green/yellow wire of the connection cable (see Fig. Electrical
connection P1.3 pumps).
P1.3 115 V/230 V
protection earth
P1.3E 115 V/230 V
green/yellow = protection earth
Fig. 2: Electrical connection P1.3 pumps
14
Bühler Technologies GmbH
AC
black = AC
Select mains and protection earth cross section according to
the rated current.
For the electrical connections especially for the protective con-
ductor use a cable cross-section from minimum 0,75 mm
Obey differing specifications on the type plate. The conditions
at the installation site must meet all specifications on the type
plate.
All parts under voltage must be protected through appropri-
ate measures against contact by persons or foreign body pro-
cedures.
P1.3 12 V/24 V
blue = - 12 V/24 V
red = + 12 V/24 V
P1.3E 12 V/24 V
2
.
brown = + 12 V/24 V
blue = - 12 V/24 V