Descargar Imprimir esta página

EHEIM eXperience 350 Manual De Instrucciones página 15

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
Press the first one down to the support frame and be sure
that the following media containers have a flush fit. In the
process, the pipe openings of the media containers must lie
on top of each other and the rubber seals must be correct-
ly fitted on the openings so as to achieve a hermetic seal.
Insert a new filter pad and cover it with the lattice screen.
ATTENTION: Fine filter pad (white) should not be placed
under the retractable handle of the media container.
Check to ensure that the sealing gasket of the pump head
fits properly and is clean.
Then lightly lubricate the sealing gasket of the pump head
with Vaseline. Place the pump head on the filter canister,
close the EZ clips and place the filter into the cabinet.
Safety instructions
Read the operating and safety instructions carefully and comply with all instructions prior to operating this device. Keep these operating instructions in a safe place.
For indoor use only. For use with aquariums.
ll electrical equipment in the water must be disconnected from the mains during care and maintenance work.
The device's power cable cannot be replaced. n external power cable or power supply unit must not be repaired. In case of cable damage, the device must no longer be used.
If an external power cable or power supply is damaged, they must always be replaced. Contact your specialised dealer or your EHEIM Service Centre. Never carry the pump
by the cable; do not bend the cable.
This equipment can be used by children above the age of 8 or by persons with reduced physical, mental or sensory capacities or a lack of experience or knowledge, provided
they are supervised or have received instruction in the safe use of the equipment and therefore understand the risks involved. Do not allow children to play with this equip-
ment. Do not allow children to clean or conduct user maintenance without supervision.
Notice: These devices produce magnetic fields which might cause electronic and mechanical disturbances or damages. This also refers to pace-
20 cm
makers. Please consult the manuals of medical equipment for the required safety margins.
ttention: Maintenance work presents the risk of crushing th fingers due to high magnetic forces.
For your own safety, we recommend to form a drip loop with the connection cable to prevent any water running along the cable from intruding into the
socket. When using a multiple socket or an external power supply unit, position them atop the filter's power connection.
Since a wide variety of varnishes and polishes are used when processing timer, the appliance feet can leave visible traces on furniture or parquet floors
as a result of chemical reactions. Therefore the device should not be placed on unprotected wooden surfaces.
To achieve optimal operational safety there must be a maximum of 180 cm between the surface of the water and the bottom of the filter.
ttention: Filter must always be operated in an upright position only.
Burning danger! Be careful when touching the heating coil of devices with integrated heater.
Take the necessary precautions when handling components that can discharge static electricity.
Do not clean the unit – or parts of it – in the dishwater. Not dishwater resistant!
Do not dispose of this product as normal household waste. Take it to your local refuse collection side.
The product is qualified in accordance with the respective national regulations and guidelines and meets EC standards.
11
Examine all three o-rings on
the double tap connector for
damage and correct fitting
and lightly grease them with
Vaseline; insert and lock in
place.
fter both of the tap levers
on the integrated double tap
connector have been open-
ed (position ON), the filter
will automatically fill up
again with water and will be
ready for operation.
Set the filter into operation
by connecting the mains
plug.
max.
180 cm
GB

Publicidad

loading

Este manual también es adecuado para:

Experience 2426