Alarms Display - Diamond AL4S/F Manual De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Problem
The electronic board remains
off.
The machine does not heat
correctly
Insufficient humidity in
proving chamber
7.1.

Alarms Display

Problem
Evaporator Low Temperature
Alarm
The display shows the following
message:
Al Low T Evap
The buzzer is active.
Cell Low Temperature Alarm
The display shows the following
message:
Low Temp Room
The buzzer is active.
Cell High Temperature Alarm
The display shows the following
message:
High Room Temp
The buzzer is active.
Causes
Power supply cable incorrectly connected.
Interrupted fuses
Protective Klixon (PTRC) interrupted.
Closed water cock
Clogged water filter
Water inlet electro valve malfunctioning
Causes
The temperature detected by
the probe is lower than the set
parameter.
The buzzer can be silenced
pressing any key
The temperature detected by
the cell probe is lower than the
set parameter.
The buzzer can be silenced
pressing any key
The temperature detected by
the cell probe is higher than
the set parameter.
The buzzer can be silenced
pressing any key
17
ENGLISH
Solutions
Check the electric
connection
Check and replace fuses
Check and replace the
component.
Open water inlet cock
Clean filter
Replace component
Solutions
 Verify the proper functioning of
the evaporator fan.
 Verify that the appliance isn't
empty.
Contact the after-sales
service.
 Verify the cell temperature
 Verify the cell temperature
 Verify the proper functioning of
the appliance.
GB

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

At68x1510-dm

Tabla de contenido