7.2.

Faults Display7

Problem
Cell Probe Alarm
The display shows the
following message:
ALL Room Probe
The buzzer is active.
Evaporator Probe Alarm
The display shows the
following message:
ALL Evap Probe
The buzzer is active.
Condenser Probe Alarm
The display shows the
following message:
ALL Cond Probe
The buzzer is active.
Humidity Probe Alarm
The display shows the
following message:
ALL U.R. Probe
Il buzzer è attivato.
RTC Alarm
The display shows the
following message:
RTC Alarm
The buzzer is active.
EEPROM Alarm
The display shows the
following message:
ALL EEPROM
The buzzer is active.
Effects
The adjustment is made with ON / OFF cycles of
compressor operation, according to the average
time previously stored and displayed in the Timer
Menu.
The buzzer can be silenced pressing any key
The adjustment is made as if the evaporator probe
is not installed, defrotings cycles end according to
the set time and the activation of the evaporator
fans is done according to the temperature of the
cell probe.
The buzzer can be silenced pressing any key
The adjustment is made as if the condenser probe
is not installed and the activation of the condenser
fans is done in parallel with the compressor.
The buzzer can be silenced pressing any key.
Humidification and dehumidification are disabled,
the alarm is stored.
The buzzer can be silenced pressing any key.
All cycles in course are blocked and all outlets
deactivated.
The buzzer can be silenced pressing any key.
All cycles in course are blocked and all outlets
deactivated.
The buzzer can be silenced pressing any key.
19
ENGLISH
Solutions
Replace the cell probe
Contact the after-
sales service.
Replace the evaporator
probe
Contact the after-
sales service.
Replace the condenser
probe
Contact the after-
sales service.
Replace the humidity
probe
Contact the
after-sales service.
When the error has
disappeared, the cycle
restarts.
Set the current date and
time.
(see specific chapter))
Replace the electric
board..
Contact the after-
sales service.