Shark SE3306C Manual Del Usuario página 4

Limpiador a vapor para superficies duras
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATING INSTRUCTIONS
Components
On/Off Power Switch: The On/Off switch
has a light that will illuminate when the
unit is plugged into the 120V wall outlet
and the switch turned to the "On" position.
Steam Ready Light: The steam ready
light located on the handle will turn "On"
when the steam is ready.
Caution:
Read the instructions for
"Filling the Water Tank" before opening
the safety cap.
Caution:
Always unplug before filling.
ALLOW UNIT TO COOL FOR FIFTEEN
(15) MINUTES BEFORE REFILLING.
Important
: Do NOT add cleaning
solutions, scented perfumes, oils or any
other chemicals to the boiler in this
appliance. Use tap water or distilled
water if the tap water in your area is
very hard.
Filling or Refilling Your Steam
Cleaner With Water
Important:
Always insure that the unit is
"UNPLUGGED" from the wall receptacle
prior to initial filling or re-filling the water
tank and has been allowed to cool for 15
minutes. Never attempt to fill this unit
under a water tap, always use the filling
funnel provided.
1. Remove the plug from the electrical
outlet and allow the steam cleaner to
cool for fifteen (15) minutes.
2. Press the steam trigger on the hand
grip to vent any residual steam
pressure that is in the boiler.
3. Place the unit on a flat, stable surface.
Push down firmly on the safety cap
and slowly turn the safety cap counter
clockwise until it is removed.
4. Place the funnel in the tank opening.
(Fig. 1) Fill with a maximum of one
filling flask or 2 cups (500 ml) of water.
Do Not Overfill. Turn the safety cap
clockwise to replace.
Note: To remove or replace the safety
cap, push down on it firmly and rotate it
clockwise to tighten or counter clock-wise
to loosen. If not depressed the cap will
rotate freely without advancing.
Note: Filling the unit with hot water will
shorten the heat up time.
Fig. 1
Warning:
Extreme care should be
taken when refilling the unit. Allow
unit to cool for 15 minutes and vent
any residual steam pressure (see
Step #2) from the boiler before
refilling. When refilling the steam
cleaner while the boiler is still hot,
there is a risk that water will squirt
back during filling and cause
scalding. Use caution when opening
the safety cap as cap may become
hot during use and escaping steam
can cause scalding.
5. Connect desired attachments onto
the flexible steam hose.
6. Plug the unit into a standard (120
volt, grounded) wall receptacle and
switch the On/Off switch to the "On"
position. Allow approximately 4-6
minutes for vapor to reach its
working temperature and pressure.
When the unit is ready for use, the
steam ready light will turn "On".
Always point nozzle outlet in a safe
direction. At the start, some water
will come out from the nozzle.
This is normal.
Note:
When the steam cleaner has
run out of water, steam output will
cease.
7. When finished using the unit, turn it
"Off" and unplug it from the electrical
outlet.
Warning
: This appliance is under
pressure. After every use, press
steam trigger button until all
pressure has been released before
removing safety cap. Allow unit to
cool for fifteen (15) minutes before
refilling.
5
OPERATING INSTRUCTIONS
Using the Trigger Lock
The steam cleaner has a steam trigger
lock that automatically engages when
you depress the steam trigger. (Fig. 2)
To unlock the steam trigger, just press it
in the direction of the hose.
Steam
Trigger Lock
Fig. 2
Using Your Steam Cleaner with
Steam Pocket
Step 1. Connect the steam pocket
accessory to the steam handle
with two extension tubes. To
attach the extension tubes one
onto the other or onto the hand
grip, press the locking button
ensuring that it fits into the hole
(Fig. 3., Fig. 4) and press the two
sections together. To disconnect,
repeat the operation by pressing
the locking button and pulling the
two sections apart.
Locking Button
Hand Grip
Fig. 3
Fig. 4
Note:
Fit the steam pocket frame with the
angle adapter onto the extension tube.
Step 2. If the angle adapter is not
attached to the steam pocket
frame, attach as follows: Hold
the steam pocket frame in one
hand and the angle adapter in
the other. Insert the angle
adapter into the opening of the
steam pocket frame
as shown in Fig. 5.
Note that the
flat side on the
nozzle must
face toward
the side of the frame
with the brass pin. Once
inserted, rotate it 90°.
Step 3. Insert the electrical power cord
into the outlet. Heating time is
approximately 4-6 minutes with
cold water. Filling the steam
generator with hot water will
shorten the heat up time.
Attaching the Steam Pocket
Towel to the Frame
Warning
: To avoid burns, always
insure the unit is "UNPLUGGED" from
the wall receptacle prior to attaching or
removing accessories.
1. Slide the steam
pocket towel over
the steam pocket
frame. (Fig. 6)
2. Bring the towel all
the way to the top
of the steam
pocket frame.
(Fig. 7)
3. Bring the hook and
latch strips that are
on the back side of
the steam pocket
towel over the
steam pocket frame
and attach to
the inside of the
front side of the
steam pocket towel.
(Fig. 8)
Note:
When replacing the steam pocket
towel, make sure that the steam pocket
frame has been allowed to cool before
removing or attaching a new steam
pocket towel.
6
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Publicidad

Tabla de contenido
loading

Tabla de contenido