CPE...-PRS...
For hat rail fitting
1. Hang all the CPE-...-PRS... onto the hat rail in the correct sequence.
2. Press the CPE-...-PRS... onto the rail until the fastening slides 5 clip into
place.
In order to link the CPE...-PRS...:
1. Place one sealing ring each between the
three compressed air channels and press
the manifold blocks together (
2. Push one connector on both sides 1
onto the self-formed rail until it engages
(
Fig. 6).
In order to fit the CPE valves (Fig. 7):
1. Press in all the valve slides 2 until they
snap into the first notch.
2. Push a seal onto each compresssed air
output.
3. Screw the valve connectors with the seals
fitted into connections 3 and 5 of the CPE
valve.
4. Place CPE valves onto the manifold block
(observe protection against torsion 4 ),
press it on and simultaneously insert
valve slides into the 2nd detent.
Valveslide and valve are then flush
against each other.
Warning
Only in this way can you prevent non-secured valves from being pushed out
when the sub-base is pressurized.
14
Fig. 5).
Fig. 5
Fig. 6
Fig. 7