2

Function and application

Valve sub-base type CPE...-PRSG-2/-3 (double or three-way) connects 5/2 or
5/3-way valves of type CPE-... with central supply connections.
Two further valves can be supplied by means of extension plate type
CPE...-PRS-2.
Different pressure zones or a bilateral pressure supply can be implemented by
means of end plate type CPE-...-PRS-EP. The maximum amount of equipment
which can be fitted is:
6 valves
– with compressed air supply on one side
or
– for each pressure zone
Fig. 2
The diaphragms have been removed from the variants CPE-...-PRSO-...
Valve sub-base CPE-...-PRS... is intended for mounting on a wall or on a hat rail.
3

Safety conditions

Note
Incorrect handling can lead to malfunctioning.
For correct and safe use of the product:
S Compare the specified limit values with your current application.
The permissible limit values, e.g. for pressures and temperatures, must not
be exceeded.
S Also observe the regulations of the trade association, the German Technical
Control Board (TÜV), the VDE and relevant national regulations.
12
12 valves
– with compressed air supply on two
sides
Festo CPE...-PRS...-Z6 1204e English