Starting And Stopping The Engine - Mosa GE 10000 LD Manual De Uso Y Mantenimiento

Tabla de contenido

Publicidad

REV.0-10/10
Check daily
!
Do not alter the primary conditions of regulation
and do not touch the sealed parts.
STARTING THE ENGINE
1) Open the fuel cock
2) Make sure that the accelerator lever
(16) is at its minimum setting.
3) Turn the starter key to position "ON".
Make sure the battery charge and oil
warning lights are lit.
4) Operate the starter
!
Using the electric starter for more than 5 seconds at a
time will overheat the starter motor and can damage it.
Turn the starter key to the START position, and hold it
there until the engine starts.
If the engine fails to start within 5 seconds, release the
key, and wait at least 10 seconds before operating the
starter again.
When the engine starts, release the key, allowing it to
return to the ON position.
5) Warm up the engine for 2 or 3 minutes.
USE
Before operating the generating set, place the accelerator
lever on the "MAX" position and leave it on that position
during all the work.

STARTING AND STOPPING THE ENGINE

NOTE
FUEL
VALVE
NOTE
STOPPING THE ENGINE
To shut down the motor in an emergency situation act
immediately on the stop lever (28).
Under normal conditions, use the following procedure:
1) stop to draw three/single-phase current from the
auxiliary sockets.
2) Set the accelerator lever or the
switch (16) to minimum position
and wait for a few minutes to allow
the engine to cool, anyway follow
the instructions contained in the
engine manual.
3) Pull the stop lever (28) until the
engine stops.
Turn the key (Q1) to the position
OFF.
Shut the fuel cock.
+ For safety reason the key must be kept by qualified
personel.
CAUTION
!
RUNNING-IN
During the first 50 hours of operation, do not use
more than 60% of the maximum output power of
the unit and check the oil level frequently., in any
case please stick to the rules given in the engine
use manual.
M
1
GE
0000 LD/GS
21
1
GE
2000 LD/GS
STOP
LEVER
THROTTLE
LEVER
FUEL
VALVE