STOPPING THE ENGINE
For shut down the motor in case of emergency, turn
the motor switch to OFF.
ENGINE SWITCH
To stop the motor under normal conditions, proceed
as follows:
- interrupt the power source, switching off
all tools connected. If a tool does not fea-
ture a power switch, lower the G.F.I. switch
lever (D);
- allow the motor to run without any load for a few
minutes;
- turn the engine switch to OFF;
- turn the fuel valve to the OFF position.
OFF
FUEL COCK
OFF
GE 4500 SX
GE 4500 SXE - EAS
GE 4500 SXE-AVR EAS
FOR EAS VERSION
Position the LOCAL START /REMOTE START (I6)
selector on LOCAL START;
WARNING
!
The start-up selector (I6) LOCAL START / REMO-
TE START enables the start-up and stop controls
for the selected position.
From the REMOTE START position, the start-up
key on the front panel is completely disabled; to
stop the generator, use the controls on the TCM
or EAS panel.
SHUT-DOWN FROM REMOTE
The unit can also be shut down by means of the
TCM remote control or EAS panel.
- Check that the EAS (B3) connector is connected
to the cable from the TCM or EAS panel.
- Verify or position the LOCAL START / REMOT
START (I6) selector on REMOTE START.
SHUT-DOWN with TCM
Follow the operating procedures for shut-down un-
der normal or emergency conditions, as described
in the paragraph SHUT-DOWN FROM FRONT
PANEL, using the key (Q1) on the TCM .
SHUT-DOWN with EAS
Shut-down is controlled automatically.
See operating manual for the EAS panel.
At the end of each use of the generator, close the
gasoline tap (87).
In case of an extended period of inactivity of the ge-
nerator, switch off the motor by closing the gasoline
tap (87); this precautionary measure serves to avoid
probable deposits in the carburettor.
+ NB.: as a safety measure the start-up key
must be entrusted to qualifi ed personnel.