Please read these user instructions in conjunction with the 3M Jupiter Reference Leaflet
where you will find information on:
• Approved combinations of headtops• Spare parts• Accessories
Save all user instructions for continuing reference.
UNPACKING
Your Jupiter Powered Air Turbo should contain:
a) Jupiter Turbo
b) Belt
c) Air flow indicator and calibration tubes
d) User Instructions
e) Reference Leaflet

SYSTEM DESCRIPTION

The 3M Jupiter is a battery powered and belt-mounted Powered Air Turbo which when
used in conjunction with one of the approved headtops forms a Powered Filtering Device.
The Jupiter system offers a choice of 4 hour, 8 hour or Intrinsically Safe (I.S.) battery
packs, a range of filter options and incorporates an electronic control unit which provides
an audible and visual warning of low battery and/or low airflow into the headtop.
APPROVALS
These products meet the requirements of the European Community Directive 89/686/EEC
(Personal Protective Equipment Directive) and are thus CE marked.
Certification under Article 10, EC Type-Examination and Article 11, EC Quality Control,
has been issued by BSI, Kitemark Court, Davy Avenue, Knowlhill, Milton Keynes, MK5
8PP, UK (Notified body number 0086).
This product complies with the European EMC Directive 2004/108/EC.
The Jupiter Powered Air Turbo (085-00-10P), when fitted with the I.S. Battery Pack and
I.S. Pouch (085-12-00P), has been approved for use in Potentially Explosive
atmospheres.

^ WARNINGS AND LIMITATIONS

Proper selection, training, use and appropriate maintenance are essential in order
for the product to help protect the wearer from certain airborne contaminants. Failure
to follow all instructions on the use of these respiratory protection products and/or
failure to properly wear the complete product during all periods of exposure may
adversely affect the wearer's health, lead to severe or life threatening illness or
permanent disability.
If you have any doubts about the suitability of the product to your job situation, it is
recommended that you consult an occupational hygienist, or call 3M Personal Safety
Technical Affairs at your local 3M office. See back of this booklet for addresses and
telephone numbers.
Use this respirator system strictly in accordance with all instructions:
• contained in this booklet
• accompanying other components of the system (e.g. 3M Jupiter reference leaflet,
Headtop and Filter user instructions).
Do not use in concentrations of contaminants above those given in the Headtop user
instructions.
Do not use for respiratory protection against unknown atmospheric contaminants or
when concentrations of contaminants are unknown or immediately dangerous to life
or health (IDLH).
Do not use in atmospheres containing less than 19.5% oxygen. (3M definition.
Individual countries may apply their own limits on oxygen deficiency. Seek advice if
in doubt).
Only use with Headtops and Spares/Accessories listed in the reference leaflet and
within the usage conditions given in the Technical Specification.
Only for use by trained, competent personnel.
Leave the contaminated area immediately if:
a) Any part of the system becomes damaged.
b) Airflow into the headtop decreases or stops.
c) Breathing becomes difficult.
d) Dizziness or other distress occurs.
e) You smell or taste contaminants or irritation occurs.
Never modify or alter this product. Replace parts only with original 3M spare parts.
When using standard 4 and 8 hour batteries - Do not use in potentially flammable or
explosive atmospheres.
When using I.S. Battery and I.S. Pouch and an appropriate Headtop (Please see
Jupiter Reference Leaflet), use of the Jupiter Powered Air Turbo is permitted in
Potentially Explosive Atmospheres (Gas) Zones 1 and 2 and (Dust) Zones 21 and
22.
Do not use in Potentially Explosive Atmospheres Zone 0 and Zone 20.
Do not use for mining applications.
Materials which may come into contact with the wearer's skin are not known to
cause allergic reactions to the majority of individuals.
These products do not contain components made from natural rubber latex.
Safe Use of Battery Chargers
To reduce exposure to hazardous voltage:
- Do not use the chargers outdoors or in wet environments.
- Do not attempt to service the chargers. There are no user-serviceable parts inside.
- Inspect the chargers and power cords before use. Replace if any parts are
damaged.
- Do not substitute, modify or add parts to the chargers.
- Only charge 3M Jupiter NiMH Batteries with the 003-00-58P and 003-00-59P
chargers.
Safe Use of Rechargeable NiMH Batteries
To reduce risk of fire and explosion associated with the NiMH batteries:
- Do not short circuit the battery. Discharge only by running in the Air Filter Unit.
EQUIPMENT MARKING
For Headtop marking please see appropriate Headtop user instructions.
For Filter marking please see Filter user instruction.
The Jupiter Powered Air Turbo is marked to EN12941.
The Jupiter Powered Air Turbo is marked with a date of manufacture (month/year).
The Jupiter Powered Air Turbo is marked IP53 (IP63 when fitted with I.S. Pouch).
The Jupiter I.S. Pouch is marked with EN60079-0, EN60079-11 Ex ib II B T3
Gb,EN61241-1, Ex tb IIIC T55°C Db, II 2 GD and SIRA Ex09Y2202X.
The Jupiter I.S. Battery is marked to EN12941 and with EN60079-0, EN60079-11 Ex ib II
B T3 Gb, EN61241-1, Ex tb IIIC T55°C Db, II 2 GD and SIRA Ex09Y2202X.
The standard 4 and 8 hour batteries are marked to EN12941.
KPackaging not suitable for food contact.
J Dispose of in accordance with local regulations
PREPARATION FOR USE
Check apparatus is complete, undamaged and correctly assembled. Any damaged or
defective parts must be replaced with original 3M spare parts before use.
Undertake pre-use checks on headtop assembly as outlined in the appropriate user
instruction.
For pre-use checks on I.S. pouch see 085-11-00P/085-12-00P user instructions.
Fit the belt to the Powered Air Turbo as outlined in the BLT-12 user instruction.
Select an approved battery (Please see Jupiter reference leaflet for list of approved 3M
batteries). Charge as shown in Fig. 1 and fit as shown in Fig. 2.
For use in Potentially Explosive Atmospheres, I.S. Battery Pack and I.S. pouch must be
fitted.
For fitting of the pouch see 085-11-00P/085-12-00P user instructions.
Battery Charging
The battery should be charged prior to first use or if unused for more than 5 days.
For charging of the 4 hour, 8 hour and I.S .batteries, please see reference leaflet.
NOTE: The battery must be charged in a safe area.
Calibration
Calibrate the Powered Air Turbo before first use and at least monthly thereafter. See
Fig. 3.
Calibration
Comments
ENTERING CALIBRATION
Note: Calibration
MODE
should be undertaken
See fig. 3. Hold switch button
without filters fitted,
for 3 seconds, second beep
using a fully charged
will sound, keep pressed
battery, and the
during calibration. Display
calibration tube (black
flashes fast during
ball). When holding the
calibration. Fan speed will
turbo ensure hands do
reduce then increase
not cover the air inlets.
gradually causing the ball to
drop then rise again. Ensure
the tube is held upright with
the horizontal line at eye
level. Observe the ball as it
rises. Release the button
when the bottom of the ball is
slightly below the line.
Ensure the ball hovers with
its bottom edge on the line.
= Slow Flash
= Fast Flash
Key
Filters
Select approved filters (please see Jupiter reference leaflet for list of 3M approved filters).
Fit optional pre-filters if required (Fig. 4) and then fit filters as shown in Fig. 5.
Airflow Check
Before use, undertake airflow check using the airflow indicator tube (white ball). See Fig.
6. To check for correct functioning of audible warning device, see Fig. 7.
4
Display
Sounder
-
After 3 seconds
+
= One Short Beep