Regularly clean the ceramic soleplate with a damp, non-metallic washing pad.
Wipe the exterior of the Steam Station with a soft cloth.
Do NOT use abrasive cleaners, detergent or other chemicals to clean the Steam Station.
Self-clean Mode
When cleaning, the steam hole of the soleplate will discharge a lot of sewage, please be prepared well in
advance. The iron has an intelligent reminder for cleaning mode and active cleaning mode respectively.
The intelligent reminder for cleaning mode means after accumulates to 36 hours using, the power in-
dicator will blink and beep for three times to remind the user to clean the iron, then long press the power
switch for 6 seconds until the power indicator blink and beep for 3 times again, this is just the time for
pressing the trigger, the iron will enter into cleaning mode and begin to discharge the sewage from the
steam hole of the soleplate; It will automatically exit the cleaning model after cleaning for 1 minute, and
the power indicator will stop blinking and beep for 3times.If the user need to exit the cleaning mode at
any time, please press 6 second until the power indicator stop blinking and beep for three times, then
cleaning mode is finished.
Change anti-scale cartridge
depending on the water hardness in your region the water softening anti-scale cartridge should be
replaced every 3-6 months.
Note: Do not use the unit without the water softening cartridge!
1- Remove the water tank from the station.
2- Pull anti-calc cartridge downwards from the water tank and remove it for changing.
Note: Be careful - there can be water inside the cartridge body.
Install a new water-softening cartridge to its place

Troubleshooting Guide

Please consult troubleshooting table below for any issues you may face prior to contacting our support
centre.
PROBLEM
Unit fails to heat up and
steam. Power indicator
light does not illuminate.
Water runs out of the holes
in the soleplate.
POSSIBLE CAUSE
Unit is not plugged in.
Water has condensed in the pipes
because you are using for the first
time or you have not used it for some
time.
The soleplate is not hot enough.
SOLUTION
Plug into electrical outlet.
Press the steam trigger away from
your ironing board until the iron
produces steam.
Decrease the steam output while
ironing at low temperature.