Switching off the product
Applicability: VPS R 100/1 M
OR VPS R 200/1 B
1.
When selecting the installation site, note the weight of
the filled cylinder and the bearing load of the floor.
Weight when filled with water
Applicability: VPS R 100/1 M
Applicability: VPS R 200/1 B
1
2.
Remove the fixing screws from the cylinder below the
pallet.
3.
Set up the three enclosed feet below the cylinder.
0020244064_00 Installation and maintenance instructions
135 kg
246 kg
2
4
3
4.
Use the adjustable feet and a spirit level to align the
product.
5
Installation
5.1
Hydraulics installation
5.1.1
Hydraulic connection
Caution.
Risk of damage caused by contaminated
lines.
Foreign bodies, such as welding remnants,
sealing residue or dirt in the water pipes, may
cause damage to the boiler.
▶
Flush the heating installation thoroughly
prior to installation.
Caution.
Risk of damage caused by heat transfer
when soldering.
The heat that is transferred during solder-
ing may lead to damage to the expanded
polypropylene around the product and to the
seals on the connectors.
▶
Protect the product's insulating casing.
▶
Do not solder the connectors if these have
been screwed onto the product.
Installation 5