8. REMOVE THE KNOCK-OUT OPENING
From inside the power pack, remove the wiring cover by removing two (2) retaining
screws and set aside. Punch out the electrical knockout hole on top of the hood. Install
the wire clamp (included in parts bag).
9. INSTALL THE 8" ADAPTER/DAMPER
Using (4) no. 8 x 3/8" screws from parts bag, assemble the adapter/damper on the top
of the power pack. To ensure proper opening of the dampers, remove shipping tape if
present. Seal all joints with metal foil duct tape to eliminate air leaks.
10. INSTALL THE 10" ADAPTER
Using (2) no. 8 x 3/8" screws from parts bag, assemble the adapter on the top of the
power pack. Seal all joints with metal foil duct tape to eliminate air leaks.
11. INSTALL THE 10" DAMPER
Install 10" damper inside the VERTICAL ductwork that will be attached to power pack.
Do not install in a horizontal ductwork or it will not open and close properly. Remove
shipping tape if present. Secure the damper to the duct with (3) no. 8 sheet metal screws
(not provided). Check to make sure damper opens and closes freely. Seal all joints with
metal foil duct tape to eliminate air leaks.
(CP45I AND CP47I SERIES ONLY)
(CP45I SERIES ONLY)
(CP47I SERIES ONLY)
(CP47I AND CP47E SERIES ONLY)
- 8 -
HR0027
M
S
L
OUNTING
CREW
OCATION
HJ0016
M
S
L
OUNTING
CREW
OCATION
HJ0026
HJ0029