HEATING SPECIFICATIONS
Hopper capacity
Efficiency
Available power (max)
Time between refuellings (min/max)
Fuel consumption (min/max)
Heatable room dimensions *
Weight including packaging
Smoke duct diameter (male)
Air intake duct diameter (male)
* The heatable room dimensions are calculated on the basis of
pellets with an lhv of at least 4300 kcal/kg and home insulation in
compliance with Italian law 10/91, and subsequent changes toge-
ther with an expected heat output of 35 Kcal/m³ per hour.
* It is also important to consider the position of the stove in the
room to be heated.
N.B.
1) bear in mind that external devices may cause interference.
2) caution: live parts. Servicing and/or inspections must be carried out by qualified staff.
(Before carrying out any maintenance, disconnect the device from the mains power supply)
ELECTRICAL SPECIFICATIONS
Power supply
On/off switch
Average power consumption
Power consumption during ignition
Remote control frequency (optional extra)
Protection on mains power supply **
Electronic circuit board protection
SAFETY DEVICES:
THERMOCOUPLE:
On the smoke outlet. It measures the smoke temperature.
It controls the ignition, operating and shutdown stages according to
the parameters set.
AIR FLOW SENSOR:
On the intake duct. It trips when the flow of combustion air is not
correct, therefore causing low pressure problems in the smoke
circuit.
SAFETY THERMOSTAT:
It trips if the temperature inside the stove is too high.
It stops pellet loading, thus causing the stove to go out.
FUSE
* two fuses are inserted on the socket
behind the stove, fitted with a switch one
is functional and the other is spare.
* *
20
kg
89,2
%
8
kW
10/22
hours
0,9/2,0
kg/h
190
m
3
155/172
kg
80
mm
40
mm
230Vac +/- 10% 50 Hz
yes
150
W
400
W
infrared
2A, 250 Vac 5x20 Fuse
2A, 250 Vac 5x20 Fuse
- 16
-
SMOKE
THERMOCOUPLE
SPEED
ROOM
SENSOR
BACKUP
BATTERY
FLOW
SCREW FEEDER
SENSOR
MOTOR
SMOKE EXTRACTION
VENTILATION
MOTOR
SAFETY
THERMOSTAT
SERIAL PORT
The Dealer can install an optional on the AUX outlet
for controlling the process of switching on and off
(e.g. telephone remote, local thermostat), located at the
rear oh the stove. Can be connected via special optional
trestle (code 620550).
BACKUP BATTERY
A backup battery is found on the control board (3-Volt
CR 2032 battery).
Its malfunction is indicated with the following messages:
(not considered a defect but due to normal wear-and-
tear): ERR 1 - ERR 2.
For more detailed information, please contact the DEA-
LER who has performed the first 1st ignition.
AUX; if this does
not turn out SERIAL
PORT
P/TEMP.
VENTILATION
ADJUSTMENT
ADJUSTMENT
MAINS
IGNITION HEATING
ELEMENT