Italiana Camini MARIÙ Instalación Uso Y Mantenimiento página 23

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
ADVICE IN THE EVENT OF PROBLEMS
PROBLEM
display-control panel off
remote control (optional) not
working
outlet air not hot
no flame appears (remember that
it only appears 5 minutes after
pressing the On/Off key)
ignition failure
The ignition/off does not start at
the time required
ERR1-ERR 2
shown on the synoptic panel
POSSIBLE CAUSES OF SHUTDOWN
If necessary, the reason for stoppage is shown on the display.
H1 low pressure alarm: problem connected with air circulation combustion and / or exhaust fumes.
H2 Smoke expulsion motor failure
SF (H3) flame stop
AF(H4) ignition failed
H5 power failure stoppage
H6 thermocouple failure or disconnection
H7 excessive smoke temperature
The message is displayed until the ON/OFF key on the panel is pressed.
Do not restart the stove until the problem has been looked into and the cause removed.
To start the stove up again after a shutdown, let the shutdown procedure end (10 minutes marked by a beep) then press the ON/OFF
key.
Never unplug the stove while it is shutting down due to problems.
It is important to report what the panel says to the dealer. Advice for each of the cases mentioned above is shown on the next page.
The chimney pots and smoke ducts connected to solid fuel devices must be brushed once a year (check whether there are regulations
on the subject in the country of installation). If inspection and regular cleaning are not carried out, the probability of a chimney pot
fire increases. In the event of a chimney pot fire, proceed as follows: do not use water to extinguish; empty the pellet hopper; contact
specialist staff after the accident before starting up again.
CAUSE
no mains voltage
excessive distance from stove
emote control battery flat
too much soot in heat exchanger
the screw feeder has not been filled Fill screw feeder (see ignition paragraph)
build up of unburnt material in
combustion chamber
Incorrect setting: clock programme
enabling programme enabling for
the day
Buffer battery in the control board
is flat
- 23
SOLUTIONS
make sure the power cord is connected check the fuse
(on the power socket)
move nearer stove
check battery and replace if necessary
clean the heat exchanger from inside the firebox
clean combustion chamber
Check according to the instructions on page 21
Replace buffer battery
-

Publicidad