BTL6-A/C/E/G500-M _ _ _ _ -PF-S115
Micropulse Transducer in a Flat Profile Housing
8
Inverting
NOTICE!
Interference in function
Inverting while the system is running may result in
malfunctions.
f
Stop the system before inverting.
Initial situation:
–
Transducer with magnet within measuring range
1. Activate inverting
►
Activate
for at least 4 s.
b
2. Invert gradient
►
Activate
a
and
simultaneously for at least 4 s.
b
After activation:
⇒
The output gradient is inverted.
⇒
Current position value is displayed.
⇒
Inverting is deactivated.
3. Abort inverting
Inverting can be aborted without any changes
being saved after the Activate inverting step.
►
Briefly activate
a
and
b
⇒
Current position value is displayed.
www.balluff.com
> 4 s b
> 4 s
simultaneously (< 1 s).
< 1 s
LED legend:
LED display Displayed values (example)
LED
a
b
a
b
LED green
LED flashing green
LED red
At 0 to 10 V At 4 to 20 mA
5.39 V
23.7 mA
5.39 V
23.7 mA
5.61 V
14.85 mA
english
15