Resetting All Values (Reset) - Balluff BTL6-A/C/E/G500-M-PF-S115 Serie Manual De Instrucciones

Ocultar thumbs Ver también para BTL6-A/C/E/G500-M-PF-S115 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL6-A/C/E/G500-M _ _ _ _ -PF-S115
Micropulse Transducer in a Flat Profile Housing
9

Resetting all values (reset)

NOTICE!
Interference in function
Resetting the values while the system is running may
result in malfunctions.
Stop the system before performing the reset.
f
The reset function can be used to restore all the settings
to the factory settings. For a reset the magnet may also be
located outside the measuring range.
1. Activate reset
Simultaneously activate
2. Reset
Simultaneously activate
After activation:
All values are reset.
Current position value is displayed.
Reset is deactivated.
3. Abort reset
Resetting can be aborted without any changes
being saved after the Activate reset step.
Briefly activate
a
and
Current position value is displayed.
16
english
a
and
for at least 4 s.
b
a
and
for at least 4 s.
b
simultaneously (< 1 s).
b
LED legend:
LED display
LED
a
b
> 4 s
a
b
> 4 s
a
b
< 1 s
LED green
LED flashing green
LED red

Publicidad

Tabla de contenido
loading

Tabla de contenido